Page 65
Corresponding Switch Table
Switch
OmniPro II
UPB 6-Button
Keypad
UPB 8-Button
Keypad
RadioRA
Master Control
ALC 4-Button
StarLite
Keypad
1
2
On Button
1 or E
1
1
1
2
3
Off Button
2 or F
2
2
2
3
4
A 3
or
G 3 3 3
4 5
B
4
or
H
4
4
5 6
C
5
or
I
5
6 7
D
6
or
J
6
7 8
7
or
K
7
8 9
8
or
L
8
9 10
9
10 11
10
Security Mode Event Buttons
Pressing the 2 (SEC) key allows you to select the event button that will be activated when a security mode changes:
0=OFF 1=DAY 2=NIGHT
3=AWAY 4=VACATION
After the security mode is selected, an additional menu appears which allows you to further specify the event button. For
example, you would like to activate an event button when you arm the system into the 3 (AWAY) mode:
WHEN
AWAY:
1=DELAY
2=CODE
3=AREA
Any of these may be selected alone or in combination. As each item is specified, the menu is redisplayed with the updated event
button description. Press the ' # ' key when done.
-
Selecting 1 (DLY) allows the user to specify whether the event button is activated at the start or end of the exit delay:
WHEN ACTIVATED?
1=START EXIT 2=END EXIT
When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is
prefixed by "A-" for "arming into".
WHEN AWAY: (END OF DELAY)
WHEN A-AWY: (START OF DELAY)
When the system is armed in the Day (instant) or Night (delay) mode, event buttons for the Day and Night modes are executed,
respectively.
-
Selecting
2 (CODE) allows you to specify that the event button is activated only when a particular code is used. You will be
prompted to enter the code:
ENTER USER CODE:
1-16 0=ALL
↓
You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through
a list of code names.
WHEN C1 AWAY:
1=DELAY
2=CODE
3=AREA
-
Selecting 3 (AREA)
allows you to specify that the event button is activated only when the specified area is armed or
disarmed. You will be prompted to enter the area:
Summary of Contents for Omni Pro II
Page 2: ...Copyright 2001 2007 Home Automation Inc All Rights Reserved...
Page 107: ......