Page 78
Entry/Exit Chime
When
Entry/Exit Chime
is set to Yes, the console(s) will beep once when a door on an entry/exit zone is opened, even if the alarm
system is off. This lets you know when someone enters and leaves.
The default setting for
Entry/Exit Chime
is Yes.
Perimeter Chime
When
Perimeter Chime
is set to Yes, the console(s) will beep once when a window or any other perimeter zone is opened, even if
the alarm system is off.
The default setting for
Perimeter Chime
is Yes.
Enable Quick Arm
The
Quick Arm
feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter
your code.
The default setting for
Enable Quick Arm
is No.
Enable Auto Bypass
The
Auto-Bypass
feature allows the system to automatically bypass an open zone when the system is armed, rather than setting off
the alarm. In some applications, it may be preferable to allow arming
only
if all zones are secure (READY).
With
Auto-Bypass
set to “No”, all zones to be armed must be secure when the system is armed. Otherwise, the console will beep
three times and display "ZONE NOT RDY". If the system is armed and a zone is open when the Exit Delay expires, the alarm
will sound.
The default for
Enable Auto Bypass
is No.
All On For Alarm
This option will instruct OmniPro II to execute an X-10 All On command in the event that any type of alarm occurs.
Beep On Trouble
If the OmniPro II detects any troubles with itself or one of the zones connected to it, it will display a message on the screen and
beep the console twice per second, continuously (i.e. beep beep...beep beep...). You can silence this sound by pressing the ' * '
key. However, if the trouble occurs again, the beeper will start beeping again.
If you do not wish to hear the beeping sound when a trouble occurs, set
Beep On Trouble
to No.
The default setting for
Beep On Trouble
is Yes.