Page 89
UNDERWRITER'S LABORATORIES REQUIREMENTS
For a complete list of requirements and restrictions when installing the OmniPro II panel in a UL Listed system, refer to the
Underwriter's Laboratories Requirements section of the Installation Manual (20I00-2).
When used in UL Listed Installations, the following items apply:
1.
The “High Security Mode” must be ON.
2.
The “Enable Auto Bypass” feature must be OFF.
3.
The “Entry Delay” shall not exceed 45 seconds for residential applications; 60 seconds for commercial applications.
4.
The “Exit Delay” shall not exceed 60 seconds.
5.
Double Delay and Quad Delay zone types shall not be used.
6.
For residential applications the sounding device may be mounted indoors. If, however, the sounding device is connected to
the "EXT HORN" terminals of the OmniPro II, then the “Outside Siren Delay” shall be set to 0.
7.
The “Dial Out Delay” shall not exceed 30 seconds.
8.
The “Beep On Trouble” feature must be ON, and CONSOLE SOUNDER must be ON.
9.
The “Swinger Shutdown” feature for each zone must be NO.
10.
The “Cross Zoning” feature for each zone must be NO.
11.
The “Exit Time Restart” feature must be NO.
Installer:
NAME: __________________________________
NUMBER: _______________________________
FIRE ESCAPE PLANNING
Your fire protection system is designed to provide warning in the event of a fire. It is your responsibility to plan your escape
routes in the event of a fire alarm. Your family should practice "fire drills" periodically to ensure that everyone is familiar with
the plan.
1.
Draw a floor plan of your home, showing location of fire and smoke detectors
.
Show two exit routes from each room: The
primary exit and an alternate escape route.
2.
Be sure that your family knows what the fire alarm signal sounds like.
3.
In the event of a fire alarm, DO NOT open a closed door. First, touch the door. If it is hot to the touch, use the alternative
escape route.
4.
Since smoke tends to rise, keep low to the floor during your escape, crawling if necessary. If you encounter any smoke,
hold your breath.
5.
During a fire alarm, do not stop to pack or gather belongings. Exit immediately and meet at a designated spot outside the
house.
6.
DO NOT return to a burning house.
7.
Notify the fire department using a neighbor's telephone.
8.
Review your escape plan and rehearse a fire alarm periodically with your family.