CONNECTING TO NETWORK VIA PC ACCESS
To access the controller over the network via PC Access:
1.
Open an OmniPro II account file.
2.
Click
Configure >> Network
.
#
If you are connecting from the local network, enter the controller’s IP address under “Network IP Address or
Domain Name”.
#
If you are connecting from the Internet, enter either the public IP address (the way to reach your local network via
the Internet) or domain name (e.g. www.homeauto.com).
3.
Enter the port number that is configured for the controller.
4.
Select the
Encryption
tab. Enter the two part encryption key as it is displayed on the console.
5.
Select
OK
.
6.
Click
Connect >> Network >> Connect
. PC Access should change from “
Off-Line
” to “
On-Line
”.
The “Modem” item on the main menu has been replaced with the “Connect” item. The submenu under “Connect” then allows
selection of “Modem”, “Serial” or “Network”. When an account file is opened, the connection type will default to “Serial”.
192.168.0.101
192.168.0.50
192.168.0.51
HAI OmniPro II
Controller
Hub or
Router
Computer
Computer
FIGURE 15 - LOCAL NETWORK
To connect to an OmniPro II controller on
a local network using HAI PC Access,
under
Configure >> Network
enter the
controller’s IP address:
(i.e. 192.168.0.101)