Page 33
3/1 FORMAT
Older central stations may require a 3/1 format. To use 3/1 format, both account numbers must be changed to 3 digit codes and
EVERY alarm code must be changed to a 1-digit code. Do not mix code lengths!
OPENING AND CLOSING REPORTS
The OmniPro II system can send opening and closing reports by user to the central station.
When the system is disarmed by user code 1-16, the communicator can call the central station and report that the system was
disarmed (opened) with the user code that was used.
When the system is armed by user code 1-16, the communicator can call the central station and report that the system was armed
(closed) with the user code that was used.
If any other code or a method disarms the system (i.e. Code 17-99, Keyswitch, or Scheduled Program), the communicator will
send a generic OPEN report to the central station. The code that is sent is defined as OTHER OPEN. If the system is armed by
any other method other than one that requires a code (i.e. Quick Arm, Keyswitch, or Scheduled Program), the communicator will
send a generic CLOSE report to the central station. The code that is sent is defined as OTHER CLOSE.
Summary of Contents for Omni Pro II
Page 2: ......
Page 21: ...Page 15 BLACK RED RED FIGURE 7 SOUNDER CONNECTIONS...
Page 71: ......
Page 72: ...HAI New Orleans LA U S A...