Page 48
SETUP MISCELLANEOUS
To configure the miscellaneous Installer Setup items, from the Installer Setup menu, press the 6 (MISC) key.
INSTALLER CODE
The Installer code allows the installer access to the Installer Setup menu. The Installer code should be changed and not given to
the customer. The Installer code cannot be used for remote phone access.
INSTALLER
CODE:
0000-9999
0000=DISABLE
↓
The default setting for the Installer code is 1 1 1 1.
NOTE:
Remember this Installer code and do not disable. There is no way to reset or retrieve the code! If the code is forgotten or
disabled, the OmniPro II controller must be sent back to the factory. Call for an RA#.
ENABLE PC ACCESS
This enables or disables the PC ACCESS feature. Factory default is enabled.
ENABLE PC ACCESS: 1
0=NO 1=YES
↕
PC ACCESS CODE
This code allows dealers to put an access code in the system that is separate from the customer's Master code and the Installer
code. Dealers can use the PC Access code to access the system by PC. The PC Access code cannot arm and disarm the system.
The PC Access code is NOT programmed from the factory. To use it, set it to any code other than 0000. To disable the PC
Access code, enter 0000 for the code.
NOTE: This item must be enabled (by entering a code) if PC Access is will be used.
PC ACCESS CODE:
0000-9999
0000=DISABLE
↕
CALL BACK PHONE NUMBER
In response to a request for remote PC ACCESS using the PC ACCESS code, the system will hang up and dial this number back
immediately. To program the CALLBACK PHONE NUMBER, enter the number then press ' # '. To remove the CALLBACK
PHONE NUMBER, press the OFF key to enter a single "-", then press ' # '.
CALL BACK PHONE NUMBER:
-
↕
OUTSIDE SIREN DELAY
If an output is configured as an "Exterior Sounder", when the alarm is "tripped", the interior sounder is turned on first. After the
OUTSIDE SIREN DELAY, the outside sounder is turned on.
This feature helps reduce annoying false alarms by signaling inside the premises first. The outside siren delay is set to 15 seconds
at the factory. You may change it to any value from 0 to 60 seconds. If you want the outside sounder to turn on immediately
when the alarm is activated, set the delay to 0. We recommend a minimum time of 15 seconds.
DIAL OUT DELAY: 15