Page 30
3/1 FORMAT
Older central stations may require a 3/1 format. To use 3/1 format, both account numbers must be changed to 3 digit codes and
EVERY alarm code must be changed to a 1-digit code. Do not mix code lengths!
OPENING AND CLOSING REPORTS
The OmniLT system can send opening and closing reports by user to the central station.
When the system is disarmed by user code 1-8, the communicator can call the central station and report that the system was
disarmed (opened) with the user code that was used.
When the system is armed by user code 1-8, the communicator can call the central station and report that the system was armed
(closed) with the user code that was used.
If the system is disarmed by any other method other than one that requires a user code (i.e. Keyswitch or Scheduled Program), the
communicator will send a generic OPEN report to the central station. The code that is sent is defined as OTHER OPEN. If the
system is armed by any other method other than one that requires a code (i.e. Quick Arm, Keyswitch, or Scheduled Program), the
communicator will send a generic CLOSE report to the central station. The code that is sent is defined as OTHER CLOSE.
DEFAULT REPORTING CODES FOR 4/2 FORMAT
CODE
ZONE
CODE
ZONE
98
TEST CODE
81
FREEZE ALARM
01
ZONE 1
82
FIRE EMERG
02
ZONE 2
83
POLICE EMERG
03
ZONE 3
84
AUX EMERG
04
ZONE 4
85
DURESS ALARM
05
ZONE 5
86
BATTERY LOW
06
ZONE 6
87
FIRE ZN TRBL
07
ZONE 7
99
CANCEL
08
ZONE 8
40
OTHER OPEN
09
ZONE 9
41
USER 1 OPEN
10
ZONE 10
42
USER 2 OPEN
11
ZONE 11
43
USER 3 OPEN
12
ZONE 12
44
USER 4 OPEN
13
ZONE 13
45
USER 5 OPEN
14
ZONE 14
46
USER 6 OPEN
15
ZONE 15
47
USER 7 OPEN
16
ZONE 16
48
USER 8 OPEN
17
ZONE 17
60
OTHER CLOSE
18
ZONE 18
61
USER 1 CLOSE
19
ZONE 19
62
USER 2 CLOSE
20
ZONE 20
63
USER 3 CLOSE
21
ZONE 21
64
USER 4 CLOSE
22
ZONE 22
65
USER 5 CLOSE
23
ZONE 23
66
USER 6 CLOSE
24
ZONE 24
67
USER 7 CLOSE
25
ZONE 25
68
USER 8 CLOSE