Page 33
The current Zone Type setting is shown on the bottom line.
To change a zone type, use the arrow keys to scroll through the list
of zone types then press ' # ' to select a new type
.
The display shows:
SELECT TYPE: 1
PERIMETER
↕
ZONE RESPONSE TIME
All zones, in the OmniLT are set to 300 milliseconds fixed response time.
ZONE TYPES
ZONE TYPE
NUMBER
DESCRIPTION
ENTRY/EXIT
0
Entry/Exit
PERIMETER
1
Perimeter
NIGHT INT
2
Night Interior
AWAY INT
3
Away Interior
2X ENTRY DELAY
4
Double Entry Delay
4X ENTRY DELAY
5
Quadruple Entry Delay
LATCH PERIM
6
Latching Perimeter
LATCH NIGHT INT
7
Latching Night Interior
LATCH AWAY INT
8
Latching Away Interior
PANIC
16
Panic
POLICE EMERG
17
Police Emergency
SILENT DURESS
18
Duress
TAMPER
19
Tamper
LATCH TAMPER
20
Latching Tamper
FIRE
32
Fire
FIRE EMERG
33
Fire Emergency
GAS
34
Gas Alarm
AUX EMERG
48
Auxiliary Emergency
TROUBLE
49
Trouble
FREEZE
54
Freeze
WATER
55
Water
FIRE TAMPER
56
Fire Tamper
AUXILIARY
64
Auxiliary
KEY SWITCH
65
Keyswitch Input
ENERGY SAVER
80
Programmable Energy Saver Module
OUTDOOR TMP
81
Outdoor Temperature
TEMPERATURE
82
Temperature
TEMP ALARM
83
Temperature Alarm
LATCHING ZONE TYPES
LATCHING ZONE TYPES ignore the status of that zone during power cycles.
If the FIRE ALARM VERIFICATION feature is being used, any device (other then FIRE or GAS) connected to an output
configured as a Switched Output (i.e. Glassbreak Detectors), must be connected to a zone configured as a LATCHING ZONE
TYPE (latching perimeter, latching night interior, latching away interior, and latching tamper).
DESCRIPTION OF ZONE TYPES
ENTRY/EXIT
ENTRY/EXIT ZONE types are intended for doors. ENTRY/EXIT ZONES are armed in security modes DAY, NIGHT, AWAY,
and VACATION. In DAY and AWAY modes, there is an entry delay (defined by ENTRY DELAY) on ENTRY/EXIT ZONES
to allow you to get into the house and turn off the alarm before it sounds. In NIGHT & DAY INSTANT mode, there is no entry
delay, so that the alarm sounds immediately if someone opens a door.