SUPERVISE BELL
This enables or disables supervision of the Bell Output, which monitors the wiring to bells and sirens. Factory default is disabled.
SUPERVISE BELL: 0
0=NO 1=YES
↕
ENABLE EMERGENCY KEYS
This enables or disables the functionality of the emergency keys on the console keypad. Factory default is enabled.
ENABLE EMERG KEYS: 1
0=NO 1=YES
↕
TIME DISPLAY
This allows you to choose between AM/PM or 24 HOUR time format.
TIME DISPLAY: 1
1=AM/PM 2=24HR
↕
DATE DISPLAY
This allows you to choose between MONTH/DAY or DAY/MONTH date format.
DATE DISPLAY: 1
1=MMDD 2=DDMM
↕
AC POWER FREQUENCY
Set this to the appropriate AC Powerline Frequency.
AC POWER FREQUENCY: 1
1=60HZ 2=50HZ
↕
DEAD LINE DETECT
NOTE: To disable OmniLT from detecting a dead line, set this item to '0'; otherwise adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line goes dead.
DEAD LINE DETECT: 8
0-15 0=DISABLE
↕
OFF HOOK DETECT
NOTE: Adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line is going off hook.
OFF HOOK DETECT: 69
20-250
↕
PICKUP AFTER HANGUP
This item is used to disable OmniLT from picking up the phone line after the called party hangs up the line.
PICKUP AFTER HANGUP: 1
0=NO 1=YES
↕
Currently, after the called party or the called party's answering machine hangs up the phone line, OmniLT picks up the line and
make its "Beep". The default setting for Pickup After Hangup is Yes.