03 Display options
The thermostat can be configured to display the following attributes:
NO WITH
RTP
RTP*
0
8
Celsius
am/pm time format
programmable
1
9
Fahrenheit
am/pm time format
programmable
2
10
Celsius
24 hour time format programmable
3
11
Fahrenheit
24 hour time format programmable
4
12
Celsius
am/pm time format
non-programmable
5
13
Fahrenheit
am/pm time format
non-programmable
6
14
Celsius
24 hour time format non-programmable
7
15
Fahrenheit
24 hour time format non-programmable
* Real Time Pricing (RTP): Select 0-7 to disable RTP display, or
8-15 to enable RTP display.
The default setting is 1.
Add 16 to each setting to disable the clock and filter reminder
displays. This may be appropriate for non-programmable and
commercial use where the time display is not desired.
04 Calibration offset
This item is used to raise or lower the current temperature reading by
1 degree Fahrenheit or 1/2 degree Celsius. If this item is set to 30,
no change will be made. Each digit below 30 will lower to
temperature, and each digit above 30 will raise the temperature.
(1 = - 29 to 59 = + 29 - Temperature units - 30 = No change)
The default setting is 30.
12