ADDRESSING THE TOUCHSCREEN 
 
OmniTouch touchscreens are connected to the same communications bus as HAI consoles.  
Each console and touchscreen must have a unique address.  The default address setting of the 
touchscreen is "1".   

 

When power is first connected to the touchscreen, if the touchscreen isn’t addressed properly 
(other consoles or touchscreens already occupy the touchscreen address) or isn’t communicating 
with the controller, the following page is displayed. 
 
 

 

 
 
To assign an address to the OmniTouch touchscreen, press and hold the HAI logo for three 
seconds.  The "Touchscreen Address" page is displayed.   
 
 

 

 
 
This page allows the installer to adjust the brightness and contrast of the touchscreen and assign 
the touchscreen address.   
 

Summary of Contents for OmniTouch 32A00-1

Page 1: ...Home Automation Inc Model 32A00 1 OmniTouch Touchscreen Installation Manual Document Number 32I00 1 Rev A August 2003...

Page 2: ...s device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Verified to comply with the limits of a Cl...

Page 3: ...RE GAUGE TYPE Wire Gauge Solid Stranded Number of positive conductors Number of ground conductors Maximum Cable Length feet 24 solid 1 1 113 24 solid 2 2 227 24 solid 3 3 340 22 solid 1 1 180 22 solid...

Page 4: ...along the pencil line 4 5 3 8 DO NOT OVERSIZE THIS CUTOUT Remove the faceplate from the touchscreen by grasping the top and bottom edges of the faceplate and carefully lifting the bottom edge away fro...

Page 5: ...ge screws in the upper left and lower right corners Turn the screws counterclockwise until the gap between the retaining flange and the housing flange is wider then the wall WALL Place the assembled u...

Page 6: ...by hanging the top of the faceplate on the top edge of the touchscreen then gently snapping the bottom onto the touchscreen REMOVING THE TOUCHSCREEN After installation if it is necessary to remove th...

Page 7: ...an be used with Omni II and a maximum combination of 16 with OmniPro II NOTE Do not exceed the maximum current limitation of the controller If more than 2 touchscreens are used the additional touchscr...

Page 8: ...chscreens and consoles can be used with OmniLT NOTE Do not exceed the maximum current limitation of the controller If more than 1 touchscreen is used the additional touchscreens must be powered from a...

Page 9: ...uchscreen if the touchscreen isn t addressed properly other consoles or touchscreens already occupy the touchscreen address or isn t communicating with the controller the following page is displayed T...

Page 10: ...ge touch the Setup icon See the Touchscreen User s Guide 32R00 1 for additional information on these items Note In the event of an AC Power failure and the HAI controller is running on backup battery...

Page 11: ...NS Size Backbox cutout 5 375 W x 4 H Faceplate 5 9 W x 4 6 H LCD View Area 3 26 W x 2 47 H Operating Voltage 9 15 VDC Maximum Current Consumption at 12 VDC 300 mA based on Maximum Cable Length as defi...

Page 12: ......

Reviews: