background image

SW12

SW12

IN-WALL SHUTTER SWITCH

20516/20120530 • SW12
ALL

 RIGHTS RESERVED HAIBRAIN©

USER MANUAL

Summary of Contents for SW12

Page 1: ...SW12 SW12 IN WALL SHUTTER SWITCH 20516 20120530 SW12 ALL RIGHTS RESERVED HAIBRAIN USER MANUAL...

Page 2: ...ources In case of improper usage or if you have altered and repaired the product yourself all guarantees expire Haibrain does not accept responsibility in the case of improper usage of the product or...

Page 3: ...Transmitters Wireless components like remotes The signals of these components will be received by a controller with transceiver functionality IRRF 7243 TM13 or CM15Pro The Transceiver will translate t...

Page 4: ...vided over more than one phase more than one group is no problem For bigger buildings or longer distances we advice you to use an active repeater instead of passive FD10 s 2 It is possible that Haibra...

Page 5: ...he power line the noise will be filtered 4 The Haibrain X 10 protocol has several mechanism to avoid modules to be switched on or off by other sources than your Haibrain X 10 Controllers However it is...

Page 6: ...allows a motor ized blind to be con trolled either manually from a momentary switch with two nor mally open contacts con nected to the unit or remotely by serial Haibrain X 10 Powerline messages sent...

Page 7: ...Switch off appropriate mains fuse and master switch Important 230V 50Hz 3A per channel max 8 HAIBRAIN U P L N DN Down Up Blue Orange key Up Down key Live 230V Neutral SW12 M U P L N DN Blue Orange SW1...

Page 8: ...of the switch Put the SW12 into the wall box and re fix the wall switch on the wall box Switch on mains fuse and master switch PROGRAMMING Before the unit can be used it has to be told what the window...

Page 9: ...er give a short key press to start the blind going down and another short key press to stop it at the bottom or you can press and hold the key until the blind is fully down and then release it At this...

Page 10: ...confusing when first trying to enter Install Mode since the user will not know how long it will take to get to the fully up position before starting to count the 5 second entry delay into Install To...

Page 11: ...d moving in the direction you want The blind will then travel to the fully open or fully closed posi tion as determined electronically by internal counting and after adding a 6 second over travel will...

Page 12: ...n for modules to switch on off sponta neously It is possible that a Haibrain X 10 System is installed at one of your neighbours using the same House Code To solve this problem try to change the House...

Page 13: ...Pro software Yes you can select SW12 at Appliances You can partly open and close the SW12 using percentages The percentages will however not fully correspond with the real situation It has only 25 po...

Page 14: ...for motors Sensitivity to power 50mV p pk 120 KHz line signals For signals 50mV AGC is applied X 10 Key codes On Off DIM DIM extended Terminals Screw terminals for L N UP relay DN relay Wires for UP k...

Page 15: ...d other relevant provisions of the following Directives DIRECTIVE 2004 108 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States re...

Page 16: ......

Reviews: