Specification
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type
R410a
Refrigerant charge
lb
2.64
Maximum allowable distance
between indoor an outdoor
in
49.2
Maximum allowable level difference
in
32.8
Refrigerant control
Capillary
Piping connections
(external diameter)
liquid
in
Φ
0.02
gas
in
Φ
0.03
drain
in
Φ
0.05
Heat insulation type
Both liquid and Gas pipes
Max. piping Length
in
49.2
Max. vertical Difference
in
32.8
Chargeless
in
32.8
Amount of Additional Charge of Refrigerant
g/in
65.6
Intemational Protection degree
IP 24
Note: the data are based on the conditions shown in the table below
h
t
g
n
e
l
g
n
i
p
i
P
g
n
it
a
e
h
g
n
il
o
o
c
Indoor: 80.6° F DB/66.2° F W B
Outdoor:
95°F DB/75.2°F W B
Indoor:68°F DB
Ou tdoor :
44.6° F DB/42.8° F WB
16.4in
3
.
Sensors list
type
Description
Qty
Ambient sensor
Its used for detecti
1
e
d
i
s
r
o
o
d
t
u
o
f
o
e
r
u
t
a
r
e
p
m
e
t
g
n
Suction sensor
Its used for detecting suction pipe temperature of compressor to
adjust gas flowing
1
Defrosting sensor
Its used for controlling outdoor defrosting at heating mode
1
1
t
a
e
h
-
r
e
v
o
f
o
e
s
a
c
n
i
r
o
s
s
e
r
p
m
o
c
r
o
f
d
e
s
u
s
tI
r
o
s
n
e
s
g
n
i
g
r
a
h
c
s
e
D
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3
8