Indoor unit
Make a hole of B mm / inches in diameter, slightly descending to outside the wall.
●
Install piping hole cover and seal it off with putty after installation
●
When the mounting plate is
fi
rst
fi
xed
1. Carry out, based on the wall studs or lintels, a
to be
fi
xed against the wall, then temporarily fasten the plate with one nail.
2. Ensure the proper level of the plate, by hanging a thread with a
weight from the central top of the plate, then fasten the plate.
3. Find the wall hole location A using a measuring tape
1
Fitting of the Mounting Plate and Positioning of the wall Hole
Lid for right
piping
Lid for under piping pipe
Fix with adhesive tape
Lid for left piping
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
●
piping with adhesive.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
●
then bend the pipe according to theposition of wall hole. When bending, be
careful not to crush pipes.
Make sure that the wires connecting the indoor and outdoor units are not covered
by the refrigeration piping insulation and are long enough to connect to the terminal
block on the indoor unit.
●
proper leveling for the plate
2
Making a Hole on the Wall and Fitting the Piping Hole Cover
Drawing of pipe
3
Installation of the Indoor Unit
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
●
[ Left
·
Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping.
●
In case of left-rear piping, bend the pipes according to the piping direction to
●
the mark of hole for left-rear piping which is marked on insulation materials.
1. Insert the drain hose into the carity of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it
out on the front side, then connect them.
3. Coat the
fl
aring seal face with refrigerant oil and connect pipes.
Cover the tubing connection with insulation materials closely, and with adhesive
tape.
Fixing the indoor unit body
Hang the unit body onto the upper notches of the
●
mounting plate. Move the body from side to side to verify
its secure
fi
xing.
In order to
fi
x the body onto the mounting plate,hold up
●
the body from the underside and then put it down
perpendicularly.
mounting plate
When you unload the indoor unit,please use
lift the bottom of the body outward
slightly and lift the unit until
it leaves the mounting plate.
agraffe mounting plate
Unloading of indoor unit body
●
your hand to raise the body , then
Remote controller (1)
AAA dry battery (2)
Mounting plate (1)
Drain hose (1)
Ø4X25 Screw (4)
Plastic cap (4)
Drain-elbow (1)
Cushion (4)
Pipe supporting plate (1)
Accessory parts
NOTE
:
The thickness of the pipe must be 0.8mm(1/16”) at least.
Selection of pipe
Insulation
material
Drain hose
Piping
Pipe supporting
plate
Indoor/outdoor electric cable
Indoor side
Outdoor side
ØBmm
Wall hole
Thickness of wall
(Section of wall hole)
Piping hole pipe
G
Model
Liquid pipe (Ø)
Gas pipe (Ø)
6.35mm (1/4")
9.52mm (3/8")
09k/12k : B= 60mm(2 3/8 inches)
18k/24k : B=70mm(2 3/4 inches)
Pitch downward for drainage
Pay attention to the following points before installation of machine:
1. Take out cushion blocks on
the left and right angle beads
as shown in the following
Figure.
2. Remove 2 gaskets under the
cross-flow fan.
3. Clean the burr on the surface of fracture to avoid the power
wire from being scratched after removing the virtual opening
of the outgoing line slot on the case by hands in indoor
power-on process.
HSU12VHGL-W
A=145mm
B= 60mm
30mm
A=145mm
B= 60mm
30mm
A=125mm
B= 70mm
30mm
System configuration
Domestic air conditioner
3
2