The marks from to
in the figure are the
parts numbers.
Please be subjected to the actual product purchased.
F
A
C
E
D
Optional parts for piping
Fixing of outdoor unit
The indoor unit should
be installed at the
recommended height
(
1.8
m).
more than 10cm
more than
15
cm
more than 10cm
more than 30cm
more than 60cm
A
A
F
C
E
D
B
Arrangement of piping
directions.
Rear left
Lef t
Right
Below
B
Attention must be paid to
the rising up of drain hose.
Indoor/Outdoor Unit Installation Drawings
The models adopt HFC
free refrigerant R32.
For installation of the indoor units, refer to the installation manual which was provided with the units.(The
diagram shows a wall-mounted indoor unit.)
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Compressor(Inside of Unit)
1.When installing the unit to wall, roof or rooftop, fix a supporter surely with nails or wires in
preparation of earthquake and strong wind.
2.Air conditioner mounted not above and one meter away from electric equipment such as
television.
more than 60cm
more than 10cm
Fix the unit to concrete or
block with bolts(10mm)and nuts
firmly and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails or
wires in consideration of
earthquake and strong wind.
If vibration may affect the house,
fix the unit by attaching a
vibration-proof mat.
Non-adhesive tape
Piping hole cover
Saddle (L.S) with screws
Connecting electric cable for
indoor and outdoor
Drain hose
Heating insulating material
more than 10cm
F
Rear right
13
Summary of Contents for 1U22KAEFRA
Page 17: ...R32 15 Safety Precautions WARNING CAUTION N Open the window and well ventilated the room...
Page 19: ...R32 R32 R32 R32 R32 R32 R32 R32 R32 Read Before Installation 17...
Page 20: ...3 R32 R32 R32 R32 R32 R32 R32 Read Before Installation 18...
Page 21: ...R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A Read Before Installation 19...
Page 24: ...Installation Procedure 22...
Page 25: ...evacuation degree Evacuate Installation Procedure 23...