F
A
C
E
D
Drawing for the installation of indoor and outdoor units
Necessary parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
The marks from
to
in the gure are the
parts numbers.
The distance between
the indoor unit and the
oor should be more
than 2m.
The models adopt HFC free refrigerant R32
more than
20cm
more than 20cm
more than 10cm
more than 30cm
more than30cm
more than60cm
more than 60cm
A
G
Necessary Tools for Installation
Driver
Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Hacksaw
Pipe cutter
Gas leakage detector or
soap-and-water solution
Hole core drill
Flaring tool
Spanner(17,19 and 26mm)
Knife
Measuring tape
Indoor Unit
Place, robust not causing vibration, where the body can be supported suf ciently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and uorescent lamps can be left.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is suf ciently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
is available as illustrated in the above gure.
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Selection of Installation Place
Power Source
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Preparation
Please be subject to the actual product purchased , the above picture is just for your reference.
Attention must be paid to
the rising up of drain hose
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual
Installation Manual of Room Air Conditioner
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Screw
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
2
1
1
4
1
4
1
Number
of
articles
Accessory parts
4X25
Connecting cable
Note:
1.Cooling only units don't have Drain-elbow
2.
Accessory parts may vary from each model,
please refer to the actual parts.
1
Summary of Contents for 1U71SABFRA
Page 11: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams Filter Filter ...
Page 12: ...Operation range Domestic air conditioner 5 Operation range 10 0 20 16 32 10 20 15 10 ...
Page 43: ...Seivice diagnosis Domestic air conditioner 41 ...
Page 44: ...Seivice diagnosis Domestic air conditioner 42 ...
Page 45: ...Seivice diagnosis Domestic air conditioner 43 ...
Page 56: ...Circuit diagrams Domestic air conditioner 54 ...