2U14CS1ERA-SM
Functions and control
17
Domestic Air Conditioner
a. the system enters the mode after receiving the ‘strength signal’.
Send strength operation signal to the outdoor system.
The mode change finishes the strength operation.
Entering ‘mute’, you can have normal operation or signal control such as timing to finish the
strength operation.
When the system is at the automatic option with the strength/ mute function, if the system enters
the cooling mode, the cooling strength/ mute function will be offered; if the system enters the
heating mode, then the heating strength/ mute function will be offered; if the system enters the
airflow mode, there will be no strength/ mute function.
5.1.6 Mute operation
the system enters the mode after receiving the ‘mute signal’.
a. Mute heating: the airflow speed is slight, the system sends the mute signal to the outdoor
system.
b. mute cooling: the airflow speed is slight, the system sends the mute signal to the outdoor
system.
When the compressor operates, the airflow speed is mute speed. EEPROM is adaptable.
Mute operation can not work under the demoisturing and airflow-sending operation.
5.1.7 Air refreshing
After receiving the signal from the remote control,(HV series: the background light of the ‘health’
logo is green. HS series: the ‘health’indicator will be lighted). If the fan operates, the negative ion
generator operates to realize the negative sending function.
If the indoor fan stops, the negative ion generator is turned off.
When the negative ion generator is turned off, if the air refreshing system is turned on, the
negative ion generator will be turned on when the fan operates.
5.1.8 Timing.
You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be
lightened. Also, the light will be turning off after the timing is finished. The followings are several
timing methods.
1.system /on timing:
The timing indicator will be lightened and the indoor system is under the
waiting mode. The light will be turned off when the timing is finished and the rest of the system
will operate under a normal condition. The timing starts since the last reception of the timing
singal. You can have the dormacy setting under the timing mode, the order of your settings will
be operated according to the timing settings.
2.system /off timing:
When the system is turned on, the timing indicator is lightened, the rest of
the system will operated under a normal condition. When set time comes, the indicator light will
be turned off and the system will be turned off. If you have set the dormant functions, the order of
your settings will be operated according to the timing settings.
3 system /on and off timing:
The settings will be completed according to the orders.
Summary of Contents for 2U14CS1ERA
Page 44: ...41 2U14CS1ERA SM ...
Page 73: ...70 Domestic air conditioner WARNING CAUTION Installation 2U14CS1ERA SM ...
Page 74: ...71 Domestic air conditioner Installation 2U14CS1ERA SM ...
Page 77: ...Installation 2U14CS1ERA SM 74 Domestic air conditioner ...
Page 78: ...Installation 2U14CS1ERA SM 75 Domestic air conditioner ...
Page 79: ...Installation 2U14CS1ERA SM 76 Domestic air conditioner ...
Page 82: ...Installation 2U14CS1ERA SM 79 Domestic air conditioner ...
Page 86: ...83 Domestic air conditioner Removal of procedure 2U14CS1ERA SM ...
Page 89: ...86 Domestic air conditioner Removal of procedure 2U14CS1ERA SM three two HOOKS ...
Page 96: ... Domestic air conditioner Removal of procedure 2U14CS1ERA SM 8 ...
Page 98: ...Domestic air conditioner Removal of procedure 2U14CS1ERA SM 9 ...
Page 102: ...99 Domestic air conditioner Removal of procedure 2U14CS1ERA SM 10 ...
Page 103: ... Domestic air conditioner Removal of procedure 2U14CS1ERA SM 11 ...
Page 105: ...Domestic air conditioner Removal of procedure 2U14CS1ERA SM 102 12 ...
Page 110: ... SSHQGL 107 10 Appendix 10 1 Piping Diagrams 2U14CS1ERA SM ...
Page 111: ...Domestic air conditioner Wring Diagram 108 10 2 Wiring Diagrams Indoor 2U14CS1ERA SM ...