2U14CS1ERA-SM
Functions and control
22
Domestic Air Conditioner
second—LCD screen lights for 0.5 second— the step-in motor fully output for 0.5 second—then
the motor doesn’t output for 0.5 second—the motor fully output again for 0.5 second. The test
program finishes.
5.1.20 Time cutting function:
connect the test program terminal on the mainboard after connecting the system to the power
circuit. The CPU of the main control will be 60 times faster.
5.1.21 Display function
When the system starts up, the background and the LCD will be fully lighted for 3 seconds. The
background colour is white.
5.1.21.1 Three-color background
The multi-color indicator is not lighted when the system is off. The mode-switching will change
the indicator colors. Red color is for heating mode, blue for cooling, water color for demoisturing,
white for automatic mode, pink for airflow sending, green for health mode and yellow green for air
refreshing. The colors health, refreshing colors are preferred to the mode colors. If different
status exist at the same time, then the last set color will be shown. The lighting key of the control
board can turn on or off the display.
5.2 The control system of outdoor unit
5.2.1
˖
The operation frequency of outdoor unit and its control
5.2.1.1
˖
The operation frequency control of compressor
The operation frequency scope of compressor
˖
Mode
Minimun operation frequency
Maximun operation frequency
Heating 34Hz
96Hz
Refrigeration 34
Hz
72Hz
5.2.1.2
˖
The starting of compressor
When the compressor is started for the first time, it must be kept under the conditions of
34Hz,56Hz,82Hz for one minute (the overheating protection of the outdoor unit air-blowing
temperature, immediately decrease the frequency when the compressor is overflowing and
releasing the pressure)
ˈ
then it can be operated towards the target frequency. When the machine
runs normally, there’s no such process. After starting the compressor for operation, the
compressor should run according to the calculated frequency, and every determined frequency
for protection should be prior to the calculated frequency.
5.2.1.3
˖
The speeds of increasing or decreasing the frequency of the compressor
The speed of increasing or decreasing the frequency rapidly 1 -----------1HZ/second
The speed of increasing or decreasing the frequency slowly 2 -----------1HZ/10seconds
Summary of Contents for 2U14CS1ERA
Page 44: ...41 2U14CS1ERA SM ...
Page 73: ...70 Domestic air conditioner WARNING CAUTION Installation 2U14CS1ERA SM ...
Page 74: ...71 Domestic air conditioner Installation 2U14CS1ERA SM ...
Page 77: ...Installation 2U14CS1ERA SM 74 Domestic air conditioner ...
Page 78: ...Installation 2U14CS1ERA SM 75 Domestic air conditioner ...
Page 79: ...Installation 2U14CS1ERA SM 76 Domestic air conditioner ...
Page 82: ...Installation 2U14CS1ERA SM 79 Domestic air conditioner ...
Page 86: ...83 Domestic air conditioner Removal of procedure 2U14CS1ERA SM ...
Page 89: ...86 Domestic air conditioner Removal of procedure 2U14CS1ERA SM three two HOOKS ...
Page 96: ... Domestic air conditioner Removal of procedure 2U14CS1ERA SM 8 ...
Page 98: ...Domestic air conditioner Removal of procedure 2U14CS1ERA SM 9 ...
Page 102: ...99 Domestic air conditioner Removal of procedure 2U14CS1ERA SM 10 ...
Page 103: ... Domestic air conditioner Removal of procedure 2U14CS1ERA SM 11 ...
Page 105: ...Domestic air conditioner Removal of procedure 2U14CS1ERA SM 102 12 ...
Page 110: ... SSHQGL 107 10 Appendix 10 1 Piping Diagrams 2U14CS1ERA SM ...
Page 111: ...Domestic air conditioner Wring Diagram 108 10 2 Wiring Diagrams Indoor 2U14CS1ERA SM ...