Dip switch

Wired Controller Wiring Instructions

InsTallaTIon

Dimensions

Unit: inch (mm)

Dip switch

on/off

function

Default setting

SW1-1

ON

  Set as the slave controller

OFF

OFF

  Set as the master controller

SW1-2

ON

  Ambient temp. display  available

OFF

OFF

  Ambient temp. display unavailable

SW1-3

ON

  Display ambient temp. from PCB of indoor

OFF

OFF

  Display ambient Temp. from wired controller

SW1-4

ON

  Auto-restart invalid

OFF

OFF

  Auto-restart valid

SW1-5

ON

  Fahrenheit

OFF

OFF

  Celsius

SW1-6

ON

  Swing angle adjustment  available

OFF

OFF

  Swing angle adjustment unavailable

SW1-7

ON

  Up/Down and Left/Right swing

OFF

OFF

  Up/Down swing 

SW1-8

ON

  Fresh Air unit

OFF

OFF

  General unit

Summary of Contents for AB09SC2VH2

Page 1: ...tures and Interface 2 Installation 3 4 Wired Controller Wiring Instructions 3 4 Dip Switch 4 Operation 5 8 Settings Functions 5 8 This system should be installed by a qualified HVAC professional Incorrect installation may cause fire water damage personal injury or death When abnormalities such as a burnt smell are detected immediately power off the main switch and contact a licensed contractor Do ...

Page 2: ...ample if the temp is 25 C 77 F it will display 25 C 77 F Humidity display function is reserved Energy Saving function This icon will be dis played only when energy saving function is set Filter Cleaning Child Lock Lock Central Motion Sensing Reserved Left Right Swing This icon is displayed only when in swing function Up Down Swing This icon is displayed only when in swing function Sleep function T...

Page 3: ...G 0 75mm2 x3 core shielded wire 300 400 ft 90 120m 16AWG 1 25mm2 x3 core shielded wire 400 500 ft 120 150m 14AWG 2mm2 x3 core shielded wire A One wired controller controls one indoor unit the indoor unit connects with the wired controller through a 3 conductor shielded cable C Two wired controllers control one indoor unit The wired controller that connects with the indoor unit is called the master...

Page 4: ...nt temp display available OFF OFF Ambient temp display unavailable SW1 3 ON Display ambient temp from PCB of indoor OFF OFF Display ambient Temp from wired controller SW1 4 ON Auto restart invalid OFF OFF Auto restart valid SW1 5 ON Fahrenheit OFF OFF Celsius SW1 6 ON Swing angle adjustment available OFF OFF Swing angle adjustment unavailable SW1 7 ON Up Down and Left Right swing OFF OFF Up Down s...

Page 5: ...the clock will default to 12 00 Within 10 seconds of the clock be ing displayed the time can be set The clock icon and minutes portion of the time display will be flashing Press the pq keys to adjust the minutes Pressing and holding the pq keys will accelerate the time adjustment With the minutes set press the TIME key The clock icon and hours portion of the time display will now begin flashing Pr...

Page 6: ...eted Timer Function Setting OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select ECO function The icon will be flashing Press the SET key to confirm the setting The ECO icon will remain on To cancel ECO function repeat the above steps NOTE The energy saving default parameters are listed below 74...

Page 7: ...s The child lock icon will disappear from the screen All normal functions of the keys will be restored Note This function requires the ON OFF key LED to be turned OFF and the screen backlight to be illuminated Press and hold the FAN keys for 5 seconds the current temperature compensation value is displayed in the upper right corner of the screen The default value is 00 Press the pq keys to change ...

Page 8: ...N OFF key LED to be turned ON and the screen backlight to be illuminated Filter Cleaning OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select the Heat Reclaim Ventilation function The icon will be flashing Press the SET key to confirm the setting To cancel the Heat Reclaim Ventilation function r...

Page 9: ...www Haier com Haier America Wayne NJ 07470 2015 Haier America Trading LLC Model YR E17 Issued Date May 2015 ...