WARNING !

CAUTION !

Please ask the dealer or specialist to install, never try by the users themselves. After the installation please
be sure of the following conditions.

Incorrect installation may cause water leaking, shock and fire hazard.

Please call dealer to install the air-conditioner.

Air-conditioner can't be installed in the envi-
ronment with inflammable gases because the
inflammable gases near to air-conditioner may
cause fire hazard.

Installed electrical-leaking circuit breaker.

Connect earthing wire.

Use discharge pipe correctly to ensure efficient
discharge.

[Location]

[Wiring]

[Operating noise]

It easily cause electrical shock without circuit
breaker.

Air-conditioner should be located in well-vented
and easily-accessible place.
Air-conditioner  should  not  be  located  in  the
following places:
(a) Places with machine oils or other oil vapours.
(b) Seaside with high salt content in the air.
(c) Near to hot spring with high content of sulfide
     gases.

(d) Area with frequent fluctuation of voltage e.g.
     factory, etc.
(e) In vehicles or ships.
(f) Kitchen with heavy oil vapour or humidity.
(g) Near to the machine emitting electric-magnetic
     waves.
(h) Places with acid, alkali vapuor.
TV, radio, acoustic appliances, etc. are at least 1
m far away to the indoor unit, outdoor unit, power

Earthing wire should not be con-
nected to the gas pipe, water pipe,
lightning rod or phone line, in-
correct earthing may cause shock.

Incorrect pipe use may cause water leaking.

supply wire, connecting wire, pipes, otherwise
images may be disturbed or noises be created.
As required, take measures against heavy snow.

Air-conditioner should be equipped with special
power supply wire.

Choose the following locations:
(a) Capable of supporting air-conditioner weight,
      don't increase operating noise and vibration.
(b) Hot vapour from outdoor unit outlet and ope-
      rating noise don't disturb neighbour.
No obstacles around the outdoor unit outlet.

Earthing

Installation of Indoor Unit

All manuals and user guides at all-guides.com

Summary of Contents for AC282AFEAA

Page 1: ...anual before using the air conditioner Please keep this manual carefully and safely CONVERTIBLE TYPE AIR CONDITIONER AC282AFEAA AC362AFEAA AC482AFEAA AC602AFEAA AC282AFERA AC362AFERA AC482AFERA AC602A...

Page 2: ...ons Safety Precautions Features and Functions Name of Parts Cleaning and Care Operation Tips Installation of Indoor Unit Trouble Shooting 1 2 3 4 5 7 8 9 10 11 24 25 28 All manuals and user guides at...

Page 3: ...rials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper di...

Page 4: ...C Indoor outdoor DB C WB C DB C WB C EAA All electrical repairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for the user of the air condito...

Page 5: ...t must be replaced by the manufacturer or authoried service agent in order to avoid a hazard In the event of a malfunction burning smell etc stop operation immediately turn off the circuit breaker and...

Page 6: ...place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision...

Page 7: ...during Heating mode the air conditioner s thermostat setting gradually lowers during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT...

Page 8: ...will change as follows Press the AIR FLOW DIRECTION VERTICAL SET button The vertical airflow direction is set automatically as shown in accordance with the type of operation selected Press the AIR FLO...

Page 9: ...FT 1 2 3 4 5 3 2 1 2 4 1 5 4 5 1 2 3 4 5 Air flow direction set Range of swing 1 2 3 4 5 1 1 2 3 1 to 3 to 3 to 4 to 5 to 5 all range Note When being switched on firstly the up down flap will be at th...

Page 10: ...nlet Grill Filter inside 9 Front panel 4 5 6 1 POWER OPER TIMER EMER 2 COMP 3 for series 282 362 482 602 8 9 1 7 Note For the wired control type unit the unit state should be checked by the the wired...

Page 11: ...accumulate dirt inside which reduces its performance We recommend that the unit is inspected regularly in addition to your own cleaning and care For more information consult authorized service personn...

Page 12: ...h another kind of heating appliance Instructions relating to heating are applicable only to HEAT COOL TYPE When using the Heating mode under conditions of low outdoor air temperature high humidity fro...

Page 13: ...e air c Near to hot spring with high content of sulfide gases d Area with frequent fluctuation of voltage e g factory etc e In vehicles or ships f Kitchen with heavy oil vapour or humidity g Near to t...

Page 14: ...connections so that the installation set available from our standard parts should be used 3 Installation work must be performed in accordance with national wiring standards by authorized personnel on...

Page 15: ...be exposed to direct sunlight 6 Take servicing etc into consideration and leave the spaces shown in Fig 1 or 2 Also install the unit where the filter can be removed 4 Install the unit where connection...

Page 16: ...lt should extend outward 30 to 50mm Ceiling Opening 640mm Ceiling panel 15mm 2 Remove the intake grilles 3 Remove the Side cover A Right and left side 4 This air conditioner can be set up to intake fr...

Page 17: ...ion bolts pass through suspension fittings at the sides four places and slide the unit back See Fig 8 1 Drill 25mm holes at the suspension bolt locations The two special nuts are provided with the uni...

Page 18: ...r unit in a semi concesled orientation make sure to reinforce the insulation of the unit on all sides Drops of water may fall from the unit if it is not thoroughly insulated Glass wool insulate 10 to...

Page 19: ...ure that the fastener used is insulated in the sane way 17 Installation of Indoor Unit Indoor unit Nylon fastner large Nylon fastner small No gap Coupler heat insulation Coupler heat insulation large...

Page 20: ...pipe VP25 outside diameter 38 mm During installation of the drain pipe be careful to avoid applying pressure to the drain point of the unit When the pipe is long install supporters Fig 11 Do not perfo...

Page 21: ...in pipe To be obtained locally Length shoud be at least 8mm Indoor unit drain port Drain pipe insulation accessories Drain pipe Indoor unit No gap 10mm or over Drain pipe Drain pipe insulation 2 If Ri...

Page 22: ...ire cutting pliers then strip the insulation to about 3 8 10mm of expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board A For solid core wiring or F cable Screw...

Page 23: ...he ground wire ELECTRICAL REQUIREMENT Electric wire size and fuse capacity Insulation tube Cord clamp Use VW 1 0 5 to 1 0 mm thick PVC tube as the insulation tube Fig 15 Table 5 30 Item Model Phase 3...

Page 24: ...ea outer case 2 When processing the cabinet iron plate be careful not to injury yourself with burrs etc 2 Fasten the round flange optional to the fresh air intake as shown in Fig 17 If using half conc...

Page 25: ...t wiring Always use a circuit that can trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole 4 Perform wiring work in accordance with standar...

Page 26: ...lectrical appliances When the current contracted capacity is insufficient change the contracted capacity 2 When the voltage is low and the air conditioner is difficult to start contact the power compa...

Page 27: ...g or shrinking because of temperature changes This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the furniture When unit is running a...

Page 28: ...et grill Are horizontal louvers at up position in heating mode Any doors or windows left open Is there any direct sunlight in the room If there are unexpected heat sources in the room Too many people...

Page 29: ...t for more than 2m continuously CT check abnormal 3 times in 30m High pressure switch acts 3 times in 30m Fault phase short of phase out of balance greatly Communication abnormal for more than 4m cont...

Page 30: ...circuit for more than 2m continuously CT check abnormal 3 times in 30m Fault phase short of phase out of balance greatly High pressure switch acts 3 times in 30m Low pressure switch acts in normal ru...

Page 31: ...ir Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com All manuals and user guides at all guides c...

Reviews: