FOR HALF CONCEALED INSTALLATION
(1) Install the indoor unit level on a strong wall which is not subject to vibration.
Installation of Indoor Unit
13
(2) The inlet and outlet ports should not be obstructed : the air should be able to blow all
over the room.
(3) Do not install the unit where it will be exposed to direct sunlight ,
(6) Take servicing , etc.into consideration and leave the spaces shown in (Fig.1 or 2) .
Also install the unit where the filter can be removed .
(4) Install the unit where connection to the outdoor unit is easy.
(5) Install the unit where the drain pipe can be easily installed.
Ceiling
INDOOR UNIT
3"(80mm)
over
6"(150mm)
over
0.4"(10mm)
over
Ceiling panel
INDOOR UNIT
3"(80mm)
over
6"(150mm)
over
0.4"(10mm)
over
Ceiling panel
Fig. 1
Fig. 2
All manuals and user guides at all-guides.com