For Preparation of Heating("Hot Keep")

"HOT KEEP"is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped

according to the room temperature which heating operation is started. Wait

for approx. 2 to 3 minute, and the operation will be automatically changed

to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost. the heating operation is stopped automatically

for 5 to 12 minutes once per approx. one hour, and defrosting is operated.

After defrosting is completed, operation mode is automatically changed

to ordinary heating operation.

When the room thermostat is actuated:

When room temperature increases and room temperature controller actu-

ates, the fan speed is automatically changed to stop under low temperature

 condition of indoor heat exchanger. When room temperature decreases,

air conditioner automatically changes over to ordinary heating operation.

WARMING OPERATION

Heat pump type warming

Defrosting operation

Atmospheric temperature and warming capacity

Period of warm-up

With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor

air with the help of refrigerant to warm the indoor space, is utilized.

When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat ex-

changer of outdoor unit along with the drop of indoor temperature. Since the accumulated frost re-

duces the effect of warming, it is necessery to automatically switch the operation to the defrosting

mode. During the defrosting operation, heating operation is interrupted.

Warming capacity of heat pump type air conditioner decreases along with the

drop of outdoor temperature.

When the warming capacity is not sufficient, it is recommended to use another

heating implement.

Since the heat pump type air conditioner employs a method to circulate warm

winds to warm the entire space of a room,  it takes time before the room tem-

perature rises.

It is recommendable to start the operation a little earlier in a very cold morning.

Summary of Contents for AD182AMEAA

Page 1: ...ITIONER AD182AMEAA AD242AMEAA AD282AMEAA AD362AMEAA AD422AMEAA AD482AMEAA AD522AMEAA AD182AMERA AD242AMERA AD282AMERA AD362AMERA AD422AMERA AD522AMERA Please read this operation manual before using th...

Page 2: ...nction 7 8 Care and Maintenance 9 For Preparation of Heating Hot Keep 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12 18 Safety Precautions 3 5 Parts and Functions 6 Cauti...

Page 3: ...an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed w...

Page 4: ...ident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending on the place of installation a circuit breaker may be necessary Drain pipe should be ar...

Page 5: ...is operated at the vicinity of such equip ment which generates steam condensed water may drip during cooling operation or it could cause a fault current or short circuit When operating the system sim...

Page 6: ...hould be H05RN F 4G 0 75mm2 All the cables shall have got the European authentication certificate During installation when the connecting cables break off it must be assured that the grouding wire is...

Page 7: ...Parts and Functions 6 Air outlet Air inlet Duct Air outlet Air inlet Duct For series 182 242 282 For series 362 422 482 522...

Page 8: ...at the air inlet or outlet Cooling is not sufficient Isn t sun shine invading direct Isn t any unexpected heating load generated Isn t the room much crowded Isn t the swing louver horizontal At HEATIN...

Page 9: ...e FAN mode during cooling To prevent frost from being accumulated on the indoor unit heat exchanger it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode E...

Page 10: ...no obstacles blocking the air inlet and air outlet of both indoor and outdoor units Make sure that the air filter is not dirty Cut in the power supply switch 12 hours before starting run Post Season C...

Page 11: ...ver to ordinary heating operation WARMING OPERATION Heat pump type warming Defrosting operation Atmospheric temperature and warming capacity Period of warm up With the heat pump type warming the mecha...

Page 12: ...as generates Hot spring area etc The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordina rily high The place where near the machin...

Page 13: ...hen strength is insufficient injury can result from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes et...

Page 14: ...of your client user a Places where chilled or heated air circulates freely When the installation height exceeds 3m warmed air stays close to the ceiling In such cases suggest your client users to ins...

Page 15: ...allation Manual For Indoor Unit For series 362 422 482 522 For series 182 242 282 3 Avoid installation and use at those places listed below a Places exposed to oil splashes or steam e g kitchens and m...

Page 16: ...drain pipe to unit pay suffcient attention not to apply excess force to the piping on the unit side Also fix the piping at a point as close as possible to the unit For drain pipe use hard PVC general...

Page 17: ...for the needed height is higher than 500 mm the back flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan Therefore make the h...

Page 18: ...duct flange Conduct the duct installation work before finishing the ceiling 8 Connection of suction exhaust ducts a Duct connection position i Fresh air inlet Inlet can be selected from the side or re...

Page 19: ...nit so that the power for the outdoor unit is supplied by terminals Item Model Phase Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum mm2 30 20 2...

Page 20: ...sly Sensor broken down or short circuit for more than 2m continuously Sensor broken down or short circuit for more than 2m continuously CT check abnormal 3 times in 30m High pressure switch acts 3 tim...

Page 21: ...HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com...

Reviews: