Installation procedure

Electric wiring

2.The wiring method of straight terminal

  For those connection wires whose end are not orbicular terminals, their
   wiring method is:

   Loosen the connecting screw, insert the end of the wire directly into the terminal block,

   and then tighten screw. Pull the wire outwards slightly to confirm it is held tightly.

3

.

Pressing method of connection wire:

     After wiring, the connection wire must be

      pressed with wire holding clamp. The wire

      holding clamp should press on the out cover

    of the connection wire. As the right figure

     shown:

Note:

  

All the wires should be copper core wires.

  

The power cable of indoor unit should be equipped according to the operation

      manual of indoor unit.

  

Before finishing vacuumizing the refrigerant pipe system, do not supply

     power to indoor unit.

       

The connection of power cable should be complied with local wiring regulation.

The wiring method of orbicular terminal

Wiring method
     1.The wiring method of orbicular terminal

       For the connection wire which end is orbicular

        terminal, its wiring method is as the right figure

         shown. Dismantle the screw and put it through the

         ring at the end of the connection wire, then connect

        it to the terminal block and tighten the screw.

Note:
   When connecting the indoor & outdoor wire, check the number of the
     indoor & outdoor terminals, the terminals with the same number connected
    together with one wire.
   Incorrect wiring will damage the controller of the air conditioner or make
   the unit work abnormally.

   

The connection type of power cord is Y connection. If the soft power

   cord is damaged, to avoid risk, it must be replaced by the manufacturer
   or theirspecific repair department or similar professional worker.

Connect wire between indoor & outdoor unit

      According to the wiring diagram in the manual of the outdoor unit to
        perform wiring work.

      Note: The marks on the terminals of the end of the connection wire should be corresponding

               one by one.

28

(Sketch map)

Correct pressing

Terminal block

Wire holding clamp

Wrong pressing

Summary of Contents for AD212BMBAA

Page 1: ...ion Instruction Fan Operation Timer On Off Function Sleep Function Timer On Off Function Maintenance Maintenance Usersí Attention Installation of Indoor Unit Installation Instruction Installation Procedure Operation Points Troubleshooting No 0010571573 Please read this manual carefully before using Please keep this manual for future use 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 19 29 17 18 ...

Page 2: ...pt temperature adjustment 3 Inner hidden type installation space saving 4 Large screen LCD display easy and convenient operation 5 Super quiet design 6 Powerful circular air volume 7 This air conditioner has POWER FAILURE RESUME FUNCTION During the operation of the unit if there is a sudden power failure when the power resumes the unit will resume the previous operation mode 8 This unit has the fu...

Page 3: ...t run After finishing defrosting the air conditioner will automatically resume operation Hint When the air conditioner is in Heating mode it absorbs heat from outside and release to indoors So the outdoor temperature may affect the Heating effect Power failure resume function please set and use this function according to actual condition After setting power failure resume function if there is a su...

Page 4: ...2 Wire Controller HEAT AUTO SET ROOM MODE FAN SWING TEMP CLOCK SET TIMER SLEEP RESET FILTER RESET ON OFF Indoor Unit 1 2 Air outlet Ventilation hole Name of Parts ...

Page 5: ...g mode display 21 Clock button Used to calibrate the time of timer and clock 16 Electric heating display Used to set working mode Auto Cooling Dehumidifying Heating Fan 18 Fan speed button Used to set fan speed Low Fan Med Fan High Fan Auto 20 Temperature Setting button 10 Health state display Used to set temperature temperature range 16 30 19 Swing button Used to set Auto Swing or Fixed air sendi...

Page 6: ...ong time When any abnormal condition scorching smell or others is found stop operation immediately and turn off the power switch Then consult your dealer Warning It may affect the physical condition or cause some health problems If continuing the operation without removing the cause it may cause trouble electric shock or fire After carefully reading this manual please keep in hand for reference If...

Page 7: ...equipment as a water heater etc around the indoor unit or the wire controller It may cause fire or Creepage If the system is operated at the vicinity of such equipment that generates steam condensed water may drip during cooling operation or it may cause Creepage or short circuit When operating the system simultaneously with a combustion apparatus indoor air must be ventilated frequently Insuffici...

Page 8: ...on the unit The LCD display of the wire controller will show the previous working state except for Timer Sleep Swing mode the operation indicator light on the wire controller will light up Choose of working mode Press MODE button each press the working mode will change as the following sequence choose FAN operation Adjusting FAN SPEED Press the FAN SPEED button to change fan speed Turn off the uni...

Page 9: ... SPEED Press the FAN SPEED button for each press the fan speed will change as the following sequence Choose the desired fan speed In Heating operation after start the unit the air conditioner will sending warm air a moment later to prevent the cold air blowing out In Dehumidifying when the room temperature drops 2 higher than the set temperature regardless the set fan speed the air conditioner wil...

Page 10: ...If depress the button the time will increase rapidly Each press the set time decreases 10 minutes If depress the button the time will decrease rapidly Set time Press the time adjusting button This LCD will show the time set the time can be adjusted within 24h AM stands for morning PM stands for afternoon Confirm the time After calibration of the clock press SET button to confirm time The time disp...

Page 11: ...tton to confirm time The time displayed is at x oíclock x minutes the unit will be turned off ON OFF Set of TIMER mode Press the TIMER button to change the TIMER mode each press the TIMER mode will change as the following sequence Turn on the unit After turning on the unit set the desired working mode The LCD of the wire controller will show working mode except for Timer Sleep Swing Each press the...

Page 12: ...unit will turn off automatically The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep Operation modes 1 In COOLING DEHUMIDIFYING operation 1 hour later in SLEEP operation the temperature will increase 1 from the set temperature another 1 hour later increase another 1 then the unit will operate continuous for 6 hours then it turns off automatically Th...

Page 13: ...sume power In order to protect the unit before using the air conditioner again turning on the power at least 12 hours in advance The windows should be hung with curtains or blinds Do not let the sun shine directly shine in the room do not let the outdoor air enter room The articles must keep dry cannot be put under the indoor unit When the humidity is over 80 or the drainage outlet is blocked the ...

Page 14: ...e touch the wire connection device cut off the power first Use stable stand support Please pay high attention when cleaning the unit Notice Clean the air filter Clean Notice Do not use the hot water over 50 to clean to avoid discoloration or deformation Do not dry the unit on fire the filter may be burnt Use cleaner or water to clean to remove dust A Use cleaner to remove dust B When the dust is t...

Page 15: ... air filter it must be reinstalled 3 Turn on the power After using season 1 In a sunny day perform half a day Fan operation to make the inner of the unit dry 2 Cut off the power If do not cut off power the unit will consume power Power cutoff can save power 3 Cleaning the air filter or air inlet and casing After cleaning the air filter it must be reinstalled For the details of cleaning please refe...

Page 16: ... unit heat exchanger sometimes the unit will automatically change to FAN mode but sooner it will resume to COOLING mode Even the operation button is set on ON within 3 minutes after the unit stops Cooling Dehumidifying or Heating mode can not start It is because the self protection of the system In this 3 minutes the air conditioner is in Fan mode During DEHUMIDIFYING there is no air blown out or ...

Page 17: ...tioner according to the following items ON OFF Is the power switch connected If the city electric power supply is normal If the wire controller is directly shined by sunshine or affected with damp If the earth creepage breaker works Please cut off power immediately and contact with suppler The power switch is not at ON position The air conditioner can not start Bad heating effect Did you adjust th...

Page 18: ...rmal phenomena such as adust smell cut off power first then ask the after sales service workers for help If still using the air conditioner in this condition the air conditioner may be damaged and causes electric shock or fire accident Trouble display E3 E5 Phenomenon of outdoor unit trouble The trouble of outdoor ambient temperature sensor The trouble of outdoor coil temperature sensor Over elect...

Page 19: ...r installation the electric box cover and the external panel shall not nip the wire Improper installation will cause heating and fire etc accidents When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant R407C If air and other things enter abnormal high pressure will occur which easily cause break and body in...

Page 20: ...on tools Accessories attached with the unit The following is the manual mentioned standard accessories please check them by yourself As the following figure shown 1 Screwdriver 2 Steel saw 3 60 70mm diameter drill 4 Spanner diameter 17 27mm 5 Spanner 14 17 19 27mm 6 Pipe cutter 7 Pipe flarer 8 Knife 9 Pincers 10 Leakage detector soap water 11 Tape measure 12 Scraper 13 Refrigerant oil No Shape nam...

Page 21: ...cles The condensate water can be drained smoothly Place can stand the weight of indoor unit Place ensures enough space for maintenance The pipe length between indoor and outdoor unit is in the permitted limit referring to outdoor unit installation part The indoor unit outdoor unit electric wire and connection wire is at least 1m away from television and radio This is to avoid the image disturbance...

Page 22: ...nt the vibration of the ceiling For details please consult to the builder 3 Install the hoisting screw Use M10 screw bolt In order to bear the weight of the unit for existed ceiling using found ation screw bolt for new ceiling using burying embedded screw bolt burying screw bolt or spot supplied other parts Before going on installation adjust the gaps with ceiling Hole in anchor Hole in plug 3 Pre...

Page 23: ...or When use high performance air filter The fan motor is equipped with red and white terminals when in factory the air sending has already been set at the standard choose When using the high performance air filter etc optional parts leading to the static pressure rise please according to the following figure shown to change the connection of the connector installed on the side of control box Red W...

Page 24: ...rpose When connecting insert the end of PVC pipe into the drain hole then use drain hose and wire fastener to fix them tight The bond can not be used to connect drain hole and drain hose Drain socket Main unit Drain hose VP 25 joint field purchased VP 25 field purchased Adhesion Clamp accessory Pipe cover large for insulation accessory 22 Drain socket Drain hose accessory Pipe cover for insulation...

Page 25: ... figure g Avoid putting the outlet of drain hose in the places with irritant gas generated Do not insert the drain hose directly into drainage where the gas with sulfur may be generated Test of drainage system a After finishing electric engineering perform drainage system test b During test confirm if the water properly passes through the pipe and there is no water leakage in the joint c In a new ...

Page 26: ...procedure Install indoor unit Before finishing the wiring work install a protruding connector on the drain hose to provide a water in hole Then if there is water leaks from the pipe system perform check Finally the water flow through the drain hose should normally pass 6 Installation of air suction and discharging duct 7 Connection of air suction and discharging duct Remove gromment Make sure to i...

Page 27: ... outer air mass strong wind and sunshine the humidity is increased There may be water drop on the outside of duct For cement and other new constructions even if not taking ceiling inner side as duct the humidity will also be so high At this time use glass fiber to perform heat preservation to the whole use iron net to bind the glass fiber Maybe exceeding the unit operation limit for example when i...

Page 28: ...or unit and outdoor unit should use shield wire And the two ends of the shield wire should be grounded otherwise the disturbance will cause unit abnormal operation Note When connecting wire please keep a certain distance between signal wire and electric wire over 10mm 4 Cover the wire controller upper cover Pay attention not to press the connection wire Note 1 The power switch and the signal wire ...

Page 29: ...ed part of indoor unit connection pipe should be thermal insulated 1 Connection of pipe Connection method For the specific max length and the max fall of connection pipe please refer to the manual of outdoor unit In order to guarantee the efficiency the pipe should be as short as possible Daub the refrigerant oil on the joint and the flared nut When bending the pipes give the roundness as large as...

Page 30: ...bicular terminal Wiring method 1 The wiring method of orbicular terminal For the connection wire which end is orbicular terminal its wiring method is as the right figure shown Dismantle the screw and put it through the ring at the end of the connection wire then connect it to the terminal block and tighten the screw Note When connecting the indoor outdoor wire check the number of the indoor outdoo...

Page 31: ...he power cable is damaged in order to avoid danger it must be replaced by the manufacturer or its specified repair center of the same qualified worker 2 Cut and flaring method Use pipe cutter to cut the pipe the burrs must be removed After inserting the flarer perform flared nut Flarer Incorr Slant Broken Uncompleted Burrs Too long A Pipe diameter Liquid pipe Dimension A mm 9 52mm 3 8î 1 0 1 2 Con...

Reviews: