Timing off 

 

When unit is working

, press “Timer” 

to start the 

function, then press “Humidity setting” button 

to set hours, timing range is from 1 to 24hours, it will increase 1 hour by each press. When time is 
up to your setting, unit will turn off. After setting, timer button flashes 5 time for confirmation.

 

 

 

Timing on 

When  unit  is 

power  on,  press  “Timer

 

  to 

start  the  function,  then  press  “Humidity  setting  ”

 

button  to  set  hours,  When  time  is  up  to  your  setting,  unit  will  turn  on.  After  setting,  timer 
button flashes 5 time for confirmation. 
 

Auto dehumidifying mode 
 

Under  this  mode,  if  room  humidity  >  setting  h5%,  compressor  will  start,  and  fan  will 

works; if room humidity

setting humidity

5%, compressor will stops, fan will work according 

to the original setting; if setting humidity

5%

room humidity

setting h5%, the unit 

will continue working according to the original settings. The initial humidity value is 50%. 

 
 

Cloth dry mode 

Under this mode, the unit will work regardless of the room humidity, compressor works, and fan 

will work from high speed, fan speed is adjustable. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AG10AA1TAA

Page 1: ...AG10AA1TAA AG12AA1TAA Model Dehumidifier dehumidifier ...

Page 2: ...Contents Safety information 2 Common Questions 3 Installation 4 Components 5 Control panel 6 Operation 7 Drainage 8 Maintenance 9 Trouble shooting 10 Specification 11 ...

Page 3: ...egularly and often 12 Please use the function of the internal drying if the device is not used for a long time This will prevent formation of mildew and unpleasant smell inside the unit 13 Do not place heavy objects on the appliance 14 Do not hang curtains or wet clothes in front of the air outlet this will overload the device 15 The drainage hose may not be installed outdoors at low temperatures ...

Page 4: ...water and install the water tank in a correct way Maybe the ambient temperature is very low and very high when operation temperature is lower than 5 or higher than 32 the unit will not work Operation temperature range for the unit is 5 32 and relative humidity at 30 80 Best operation temperature range is 16 32 Q Why the outlet air is a little warm It is not a fault when room air is condensed by th...

Page 5: ...ring the operation keep unit closed to the door and windows closed to save energy Make sure no block at air inlet and outlet Put the unit is stably laid on as the following photo At least 20cm from the front back or the left right and at least 50cm from the top ...

Page 6: ...Components Front Control panel Water Tank Filter Back Handle Air Outlet Continuous Drainage Mouth Wires Hook ...

Page 7: ... to change fan speed high low high Display screen In Auto dehumidifying or cloth dry mode it will indicate the actual room humidity In timing mode it indicates the setting time Humidity setting In Auto dehumidifying mode press the key to set humidity humidity range is from 30 to 80 it decreaseS 5 by every press Mode When power on or timing power on press this button to choose auto dehumidifying or...

Page 8: ...is up to your setting unit will turn on After setting timer button flashes 5 time for confirmation Auto dehumidifying mode Under this mode if room humidity setting humidity 5 compressor will start and fan will works if room humidity setting humidity 5 compressor will stops fan will work according to the original setting if setting humidity 5 room humidity setting humidity 5 the unit will continue ...

Page 9: ...ll the water tank as the following photo Note Before putting in the water tank please ensure the float is flexible 2 Continuous drainage optional To connect a water pipe in the back inner diameter is 9mm water can be drained continuously Please check if the pipe is stably connected with the drainage mouth or water will flow out Note Water pipe cannot be too long usually 0 6m the height cannot surp...

Page 10: ... if dehumidifier is not used for long time Please do not use benzene alcohol gasoline or other chemical reagent to clean unit Clean the water tank with soft cloth Use wet cloth to clean appliance surface do not use detergent or grinding sponge to damage surface Clean filter at least one time every two weeks ...

Page 11: ...not so obvious Dehumidifying function is ineffective Is air outlet or air inlet blocked Clean the air outlet or air inlet No outlet air Is filter blocked Clean the filters Is the unit laid stably Put the device in a flat floor Too loud noise Is air outlet or air inlet blocked Clean the filters There is sound of water flow It is refrigerant flowing Water leakage Drainage pipe is not tightly connect...

Page 12: ...Specification Model YDZ 10D Voltage 220 240V 50H z Dehumidifyin g capacity 30 RH80 10L day Rated power 240W Water tank 1 8L Net weight 9 5kg Size mm length dept h height 296 x 217 x416 ...

Reviews: