-15-
Commercial Air Conditioner
Model: AU18
/22
2XFERA
AS072/092/122XVERA
4. The wiring method should be in line with the local
wiring standard.
5. The power cable and connecting cable are self-
provided. The requirement of the power cable to the
outdoor unit: H05RN-F 3G 4.0mm
2
All the cables shall have got the Local authentication
certificate.
6. The breaker of the air conditioner should be all-pole
switch; and the distance between its two contacts
should be no less 3mm. Such means for disconnection
must be incorporation in the fixed wiring.
7. The waste battery shall be disposed properly.
All electrical repairs must be carried out by qualified
electricians. Inadequate repairs may result in a major
source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that
carry refrigerant by piercing or perforating the air
conditioner's tubes with sharp or pointed items,
crushing or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant spurts out
and gets into eyes, it may result in serious eye
injuries.
Do not obstruct or cover the ventilation grille of the
air conditioner. Do not put fingers or any other things
into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.
In no case should children be allowed to sit on the
outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
Model
H05RN-F 3G 4.0mm2
2. If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a similar
qualified person.
3. If the fuse on PC board is broken please change it
with the type of T 3.15A /250VAC or T 25A/250VAC.
Please check the circuit diagram about the fuse
replaced.
Cautions
Safety precautions
AU182XFERA
Cable type
AU222XFERA
5.1 Outdoor Installation
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum:D.B/W.B
32 C/23 C
Minimum:D.B/W.B
18 C/14 C
Maximum:D.B
43 C/26 C
Minimum:D.B
Maximum:D.B
27 C
Minimum:D.B
20 C
Maximum:D.B/W.B
24 C/18 C
Minimum:D.B/W.B
-15 C
To ensure proper installation, please read this safety precautions carefully before the installation. After
installation, start the unit correctly and ensure that you show the customer how to operate and maintain
the units.
WARNING!
CAUTION!
Incorrect operations may result in injuries or machine damages; in some cases may
cause serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
10 C/6 C