not full
3. Refrigeration quantity of compressor
is reduced.
2Clean the capillary and filter.
3.Change compressor.
Evaporator
frosts too
rapid, frost
layer too thick
or frozen to
ice
1. Food put into freezer contains water.
2. Too much food has been stored.
1. Please let or make food dry
after cleaning, then store it.
2. Store only corrects quantity of
food.
Electricity
leakage of
freezer body,
you will feel
tingle when
touching by
hand
1. Freezer body has not been connected
to the ground.
2. The compressor terminal contacts body
shell and causes short circuit.
3. When the components of electrical
system get wet, insulation ability is
dropped, electricity leaks.
1. Make the ground connection
as stipulated.
2. Change
compressor.
3. Check carefully step by step, if
insulation is seriously damaged,
please change; remove wet parts
and put them into drying box to
make them dry.
Electricity
leakage of
fan
1. Environment
temperature too high or
insulation ability of insulator is dropped.
2. There is short circuit between fan coils
or the fan coil is burned.
1. Change
fan.
2.Change fan.
Fan too noisy
1. The blade of fan is blocked or fan
supporter is loose.
2. The clearance of fan axle is too big.
1. Clear obstacles around the
fan or tighten the supporter.
2. Change the fan.
The fan
doesn’t run
1. Check if any connection has come off.
2. Check is the fan is burned.
1. Change the fan.
2. Change the fan.
Electricity
leakage of
temperature
controller
1. The service time is too long.
2. The environment is too dirty.
3. Humidity is too high.
1. Change
temperature
controller.
2. Use brush to remove dust.
3. Make the temperature dry
and control the environment
humidity.
Temperature
controller out
of order
1. There is leakage of temperature
sensing medium.
2. Damage of cam of contacting point
spring, etc.
Change temperature controller.
The probe of
temperature
sensing tube
doesn’t
contact
evaporator
well
It has not been mounted to position or
changed during transportation.
Mount it again.