11
Gas Supply Line
•
The gas supply line should be ½" (1.3 cm) pipe and must have an individual
manual shut-o
valve installed within 6 ft. (183 cm) of the dryer in accordance
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada with the
Natural Gas and Propane Installation Code, B149.1.
•
The shut-o
valve should be easy to reach for opening and closing.
•
A
"
" NPT minimum plugged tapping must be installed immediately upstream of
the shut-o
valve. This
Þ
tting is used to check the gas pressure.
•
The supply line should terminate with a
!
" NPT
ß
are adapter
Þ
tting.
¹⁄₂
" NPT Gas Supply Line
Gas Shut-O
Valve
¹⁄₈
" NPT Minimum Plugged Tapping
!
" NPT Flare Adapter Fitting
B
C
D
A
EXHAUST SYSTEM REQUIREMENTS
WARNING
This section describes the requirements for a safe and efficient exhaust
system. Failure to follow these instructions can result in poor dryer
performance, damage to the dryer, and a fire hazard.
DUCTING
•
If your current exhaust system is constructed of plastic or metal foil
ß
exible
ducting, replace it with rigid metal ducting.
•
Use only 4” (10.2 cm) diameter rigid metal ducting.
•
When making turns in the ductwork, use 45° elbows rather than 90° elbows. This
provides better air
ß
ow and can reduce the accumulation of lint in the exhaust
system.
90° - Good 45° - Better