8

•As the freezer is sensitive to the environmental temperature, it can not operate 
normally if it is installed in an environment other than the above. Please use it after 
improving the environment. 

•It is prohibited to install the freezer in the open air environment. When the freezer 
gets wet in the rainwater, it may cause leakage of electricity or electric shock accident.

•Ambient temperature: 16°C to 32°C , 18°C to 25°C are optimal and air conditioning system is 
required as necessary.

Ambient humidity: below 85%Rh.

Avoid excessive dust.

Avoid mechanical swing or vibration.

The freezer shall operate at an altitude 2,000 m.

Input voltage: within the range of 220-240V~.

For normal operation and optimum performance level of the freezer, its installation place shall 
conform to the following conditions:

• It can not be installed in a narrow, small and airtight space, the door frame of the room for placing it 
shall not be less than and lower than this product, and shall at least guarantee its normal passing in 
and out so as to avoid any maintenance diffi culty and failure of in-time repair in occurence of machine 
fault, casuing spoilage to the stored articles.

• The ground at the installation place shall be solid and fl at.

• It shall be well-ventilated without direct sunshine.

• Do not share a socket with other equipment, the plug and socket shall be well connected.

• Do not distort nor stress the power cord.

• If it is required to lengthen the power cord, the section area of the lengthened wire shall not be less 
than 2mm

and the length shall not be longer than 3m.

• Ckeck tje operationg voltage before use, at the area where the voltage is not stable, use of a voltage 
regulator suitable for the motor load shall be considered for voltage stabilization. So that the normal 
input voltage is stabilized at 220-240V~, the power of the voltage regulator is greater than 2000W.

• The freezer shall be guaranteed with reliable earthing.

• If the power socket has earth wire, check if the earthing is good before use.

• The interior is used for storing fl ammable and explosive reagents.

• The appliance is not suitable for use in explosion-hazard areas.

•Do not make freezer earthing via gas piping, water supply pipe, telephone line or 
lighting rod that may easily cause an electric shock.

•After installation, the power plug must be accessible to facilitate unplugging of the 
power cord in emergency. No articles shall block out the air vent of the freezer.

Product Installation

21

Anti-static operating instruction

1.clean plastic parts with a dramp cloth only.

2.Do not use a dry cloth to clean plastic parts.

3.Danger of sparks due to electrostatic discharge.

4.Warning - potential electrostatic charging 

   hazard - see instructions.

• In order to prevent an electric shock or personal injury be sure to cut off the power of 
the freezer before conducting any repair to the freezer.
• Make sure not to suck medicine or suspended particles around the storage box when 
maintaining the freezer, otherwise, it will hurt your health.

The inner of the freezer are made of two types of plastic materials. The fi rst is 
the permanent antistatic plastic material, which can be used to clean the plastic 
any time. The other one is the ordinary plastic material, which requires a regular 
cleaning of the plastic.

• Cut off te freezer power if the freezer is not in service for a long time;
• Open the freezer's door and take out the inner drawer;
• Make thorough cleaning of the freezer;
• Clean the drawers; Wait till the freezer and the drawers are dried in the air, and repalce the drawers 
in the freezer.
• Close the door of the freezer and cover it with a plastic bag for sealing up.

Inner cleaning

Dry the bottom of bin

Stopping freezer

Cleaning and Maintenance

After under operation for a certain time, the frost will be formed on the inner wall of freezer, which 
might affect the normal refrigerating effect if it is too thick, and might consume more energy. 
Therefore, after a certain time of operation, when the thickness of frost reaches to 5mm around, you 
should use the attached defrosting shovel to clean it according to the following steps
• Take out the articles kept in the bin and move to appropriate site;
• Switch off the power switch;
• Open the outer and inner doors for a while in order to defrost naturally;
• After frost melts well, discard the water from the drawers or drain it from the drainage hole;
• Dry the bottom of bin;
• Restart the equipment after the bin is cleaned well;
• Put all articles back in the bin that has already been cooled down.

• Do not use knife or screwdriver or similar tools with sharp edges to defrost. 

• Defrosting should be carried out once per month, up to once per three months.

Laboratory Deep Freezer with explosion-proof interior

Interior Temp

.

 Range 

Certification No.:CML 18ATEX4058X
Serial No.:In the Barcode
Qingdao Haier Biomedical Co., Ltd.

Internal

II3/- G Ex ic IIC T6 Gc

-10 ~ -25

℃(

DW-25L92FL/SF

-10 ~ -30

℃(

DW-30L278FL/SF

Summary of Contents for DW-25L92FL

Page 1: ...lity checker Model DW 25L92FL DW 25L92SF DW 30L278FL DW 30L278SF Laboratory Deep Freezer with explosion proof interior Operation manual Our company reserves the right to interpret the Operaiton Manual Read the Operation Manual carefully before using your appliance Keep the Operation Manual in a safe place Appearance color and layout of the door may vary Translation of the original instruction The ...

Page 2: ...29 ...

Page 3: ...uality hermetically sealed compressors and other components for a high efficiency performance User friendly design with microprocessor control for smart and carefree operation adjustment not needed High performance thermal insulation for excellent temperature protection The product application scope Temperature setting range 10 25 30 Computer control and temperature numberic display with temperatur...

Page 4: ...pray coated steel plate Permanent anti static sheet PS plate Condenser Evaporator Wire and tube type plate type Temperature Control Microprocessor controlled Refrigerant R600a 52g R290 105g Net weight 46kg 115kg Setting temperature range 10 25 10 30 Voltage Input power 220V 240V 50Hz 160W 220V 240V 50Hz 330W Anti shock Safety Classification I I Climate type Noise Level Lp 4 27dB A 4 40 dB A Foaming...

Page 5: ... cause a fire or electric shock If it is required to lengthen the power cord the section area of the lengthen cord must not be less than 2mm2 and the length shall not be longer than 3m Otherwise it may cause a fire or electric shock The power cord of this freezer is provided with a three wire earthing plug complying with the standard 10A three wire earthing socket Never cut or remove the earting pin...

Page 6: ...ing toxic hazardous or radioactive articles please use the freezer in a safety zone Improper use may bring hurt to human health or environment If the freezer is left unused for a long time in an unattended area make sure that children will not approach the freezer and the freezer door will not be closed completely Disposal of discarded freezer shall be conducted by the relevant personnel The appli...

Page 7: ... material in sealed container before storing into freezer When restarting the freezer after a power failure of power off it is required to check the setting of the freezer Change of setting may spoil the articles stored Once the power of the freezer is cut off wait for over 5 minutes before it is reconnected so as not to damage the compressor or the system Put on your gloves at time of maintenance...

Page 8: ...our after the door is closed The freezer is equipped with security door lock Please keep the key properly Once the key is lost the door body of the freezer will not opened Lock of the upright freezer The lock of the upright freezer shall be locked when the freezer is powered on or it will cause cold air leakage and frosting which will affect the performance Cleaning and Defrosting of the freezer 1...

Page 9: ...ise it may be triggered by the rapid cooling and shrinkage of the internal components inside the equipment and it shall be cooled gradually to avoid excess in decrease of temperature in a short time FAQ 7 DW 25 30 L 92 278 FL SF Deep Freezer Character Point Temperature 25 30 Upright Storage Volume FL Explosion proof type with electrostatic protection SF Explosion proof type without electrostatic p...

Page 10: ... the power cord in emergency No articles shall block out the air vent of the freezer Product Installation 21 Anti static operating instruction 1 clean plastic parts with a dramp cloth only 2 Do not use a dry cloth to clean plastic parts 3 Danger of sparks due to electrostatic discharge 4 Warning potential electrostatic charging hazard see instructions In order to prevent an electric shock or perso...

Page 11: ...ature display area Impulsive sound alarm Lower limit alarm for temperature If the temperature sensed by the sensor is lower than 50 The alarm light will flash and ELo will be shown on the temperature display area Impulsive sound alarm Power failure alarm Power failure of the freezer The inner temperature will be shown for 0 5s and disappear for 0 5s on the temperature display area by turns for 24h ...

Page 12: ... delay t1 default to 15min Communication fault The display board and the power board are unable to send and receive data for 5 times continuously E03 Alarm indicator flashes and E03 code is displayed Buzzing alarm Sensor is abnormal Fault occurs on the main sensor in freezer E04 Alarm indicator flashes and E04 code is displayed Buzzing alarm Door ajar alarm The door is opened or not closed tightly E...

Page 13: ...e will be displayed after start When inquiry if press Fn for 1 second this record will be deleted the value will be changed to measured value by current sensor 2 Use and to roll the parameter Ho1 or Lo1 3 Press SET to confirm the parameter and then display the value of parameter 4 Press SET to return to the displayed parameter 5 Use and again to roll for inquiring another parameter 6 Press SET to c...

Page 14: ...me so as to prevent electric shock leakage of electricity or fire due to aging of the power cord If the freezer is left unused for a long time in an unattended area make sure that childrenn will not approach the freezer and the freezer door can not be closed completely 17 DW 30L278FL 278SF Power on indication Indicates that power is On Locking indication Indicates that the screen have been locked R...

Page 15: ...or reduced by press of button or button Press Set button after reaching the set value the parameter will be changed and saved Press Alarm button to exit the parameter setting and display the current inner temperature Parameters code Parameter meaning Min value Max value Unit Default value Ts Control temperature setting 30 10 25 ALH High temperature alarm value setting Ts 1 Ts 6 20 ALL Low temperat...

Page 16: ...14 DW 30L278FL 278SF Control panel Pad lock Drawer Lock Caster and leveling leg Lock kits 15 DW 25L92FL 92SF DW 30L278FL 278SF Thermostat FN SET ...

Reviews: