Indicating of working status of display panel
】
1.
The
refrigerator
will
enter
starting
status
after
it
is
switched
on,
and
all
parameters
on
the
display
screen
will
be
saved
as
those
before
the
last
power
interruption.
The
displayer
will
display
the
actual
temperature,
setting
temperature
and
current
voltage.
Indication
of
working
status
of
the
display
panel:
“Lock”
indicating
lamp:
if
the
lamp
lights,
indicating
all
settings
are
locked,
to
prevent
misoperation.
“Network”
lamp:
if
it
lights,
indicating
the
network
system
has
been
in
operating
status.
“Operating”
lamp:
if
it
lights,
indicating
the
compressor
is
operating.
“Stabilization”
lamp:
if
it
lights,
indicating
the
voltage
booster
is
boosting
or
reducing
the
voltage.
【
115V
】
When
the
refrigerator
is
applied
to
115V
circuit,
when
the
input
voltage
drops
to
98V,
the
booster
will
be
connected
to
boost.
When
the
input
voltage
increases
to
113V,
the
booster
will
be
disconnected,
with
boosting
amplitude
12V;
when
the
input
voltage
increases
to
125V,
the
booster
will
be
connected
to
reduce
voltage.
When
the
input
voltage
drops
to
120V,
the
booster
will
be
disconnected,
with
reduction
amplitude
12V.
When
the
input
voltage
drops
to
95V,
the
compressor
is
in
operating
for
a
long
time,
without
shutdown.
The
alarm
lamp
flashes,
free
from
buzz
alarm;
when
the
input
voltage
increases
to
136V,
the
compressor
will
operate
as
per
the
normal
procedure,
at
the
same
time
the
alarm
lamp
flashes,
free
from
buzz
alarm.
【
220V
】
When
the
refrigerator
is
applied
to
220V
circuit,
when
the
input
voltage
drops
to
200V,
the
booster
will
be
connected
to
boost.
When
the
input
voltage
increases
to
210V,
the
booster
will
be
disconnected,
with
boosting
amplitude
12V;
when
the
input
voltage
increases
to
230V,
the
booster
will
be
connected
to
reduce
voltage.
When
the
input
voltage
drops
to
215V,
the
booster
will
be
disconnected,
with
reduction
amplitude
12V.
When
the
input
voltage
drops
to
184V,
the
compressor
is
in
operation
for
a
long
time
under
no
shutdown.
The
alarm
lamp
flashes,
without
buzz
alarm;
when
the
input
voltage
increases
to
253V,
the
compressor
will
operate
as
per
the
normal
procedure,
at
the
same
time
the
alarm
lamp
flashes,
without
buzz
alarm.
“Backup
system”
lamp
lights,
indicating
the
system
is
in
operating
status.
Summary of Contents for DW-86L288
Page 7: ...7 88 Product appearance DW 86L388 486 628 728 828 ...
Page 8: ...8 88 DW 86L288 DW 86L338 388A ...
Page 9: ...9 88 DW 86L490 DW 86W100 ...
Page 10: ...10 88 DW 86W420 ...
Page 11: ...11 88 Dimensions DW 86W100 ...
Page 12: ...12 88 DW 86L490 ...
Page 29: ...29 88 product nameplate For example DW 86L338 ...
Page 55: ...55 88 PICTURE 2 PICTURE 3 PICTURE 4 U Unit Pa 3Pa ...