-------Internal training document for Haier service provider. External disclosure is prohibited --- Classification
21
21
ULT Full Series Refrigerant Charge
Model
Refrigerant
(Type/Charge) 1
Refrigerant (Type/Charge)
2
Refrigerant improvement
time
High temperature stage
(g)
Low temperature stage (g)
R134A
R404A
R290
R508
B
R29
0
R2
3
R17
0
DW-86W100
/
500
/
105
12
/
/
DW-86W420
/
540
/
160
20
/
/
Since Apr. 1, 2012
DW-86W420
(old)
180
420
/
/
20
14
0
/
DW-86L288
/
540
/
210
20
/
/
Since Jan. 10, 2011
DW-86L288
(old)
165
385
/
/
24
13
5
/
DW-86L338
/
570
/
195
20
/
/
DW-86L388
/
560
/
235
20
/
/
Since Jan. 12, 2011
DW-86L388
(old)
95
525
/
/
28
14
2
DW-86L388A
/
550
/
195
20
/
/
DW-86L486
/
580
/
280
30
/
/
DW-86L490
/
580
/
285
20
/
/
Since Jan. 1, 2014
DW-86L490
(old)
/
550
285
30
/
/
DW-86L628(220
V)
90
810
/
315
30
/
/
Since Dec. 25, 2010
DW-86L628115
V)
/
880
/
295
30
/
/
DW-86L628
(old)
180
420
/
/
30
18
0
/
DW-86L728
/
850
/
305
30
/
/
Since Mar. 10, 2015
DW-86L728
(old)
90
800
/
325
30
/
/
DW-86L828
80
750
/
325
30
/
/
DW-86L578J
/
/
150
/
5
/
75
DW-86L728J
/
/
150
/
5
/
90
Summary of Contents for DW-86L338