33
/
88
⑥
Height
of
the
working
position
of
the
equipment:
less
than
2000m
⑦
Operating
humidity:
less
than80%RH.
If
the
maximum
operating
temperature
is
32
℃,
the
humidity
shall
be
less
than
57%RH.
⑧
Input
voltage:
Within
220±10%.
Notes:
Because
the
ultralow
equipment
is
sensitive
to
the
ambient
temperature,
if
the
machine
can’t
operate
normally
if
it
is
installed
in
the
environment
other
than
the
above
ones,
then
it
can
be
applied
again
after
the
environment
is
improved.
3.2
Matters
needing
attention
of
the
product
①
At
least
a
20cm
clearance
shall
be
reserved
between
the
wall
and
the
back
of
equipment
②
Ground
of
the
installation
site
must
be
level,
whose
ambient
temperature
shall
not
exceed
30
℃
.
③
The
equipment
shall
be
applied
under
an
environment
of
25
℃
.
If
the
temperature
is
too
high,
then
the
air
conditioner
is
required
for
solution.
④
Fix
the
machine
well
with
fixed
bolts.
⑤
Good
ventilation
indoor.
⑥
Don't’
use
the
same
socket
with
the
plug
of
other
equipment,
the
plug
and
socket
must
be
connected
securely.
⑦
Please
note
that
the
power
line
shall
not
be
twisted
or
pressed.
⑧
If
the
wire
shall
be
lengthened,
standard
of
the
feeder
line
will
be
230V
and
15A,
and
the
lengthened
part
shall
not
exceed
3m.
⑨
The
equipment
is
especially
used
for
208~230V
,
50/60Hz
power.
Please
check
the
operating
voltage
before
use,
if
it
is
lower
than
180V,
then
the
transformer
will
be
used
to
boost,
and
the
total
transformation
power
shall
be
greater
than
3kW.
When
the
voltage
is
higher
than
230V,
the
transformer
will
be
used
to
reduce
the
voltage.
For
the
areas
with
unstable
voltage,
the
stabilizer
shall
be
applied,
to
guarantee
the
normally
input
voltage
to
be
stabilized
at
220V±10%.
Power
of
the
stabilizer
shall
be
greater
than
3kW.
⑩
The
equipment
must
be
guaranteed
to
reliably
ground.
⑾
If
the
power
plug
is
equipped
with
the
earth
wire;
please
check
its
output
before
use.
⑿
If
the
socket
hasn’t
any
earth
wire,
firstly
connect
the
earth
terminal
of
the
equipment
to
the
earth
wire,
then
connect
the
other
end
of
the
earth
wire
to
a
copper
plate,
finally
bury
it
Summary of Contents for DW-86L338
Page 7: ...7 88 Product appearance DW 86L388 486 628 728 828...
Page 8: ...8 88 DW 86L288 DW 86L338 388A...
Page 9: ...9 88 DW 86L490 DW 86W100...
Page 10: ...10 88 DW 86W420...
Page 11: ...11 88 Dimensions DW 86W100...
Page 12: ...12 88 DW 86L490...
Page 29: ...29 88 product nameplate For example DW 86L338...
Page 55: ...55 88 PICTURE 2 PICTURE 3 PICTURE 4 U Unit Pa 3Pa...