38
/
88
【
Indication of alarm status
】
“High
temperature”
indicating
lamp:
if
the
lamp
lights,
indicating
the
alarm
display
when
the
temperature
inside
the
refrigerator
is
higher
than
the
setting
value.
“Low
temperature”
indicating
lamp:
if
the
lamp
lights,
indicating
the
alarm
display
when
the
temperature
inside
the
refrigerator
is
lower
than
the
setting
value.
“Over
voltage”
lamp
lights,
indicating
the
voltage
is
lower
than
184V
(95V)
or
higher
than
253V
(136V),
buzzing.
“Too
high
ambient
temperature”
indicating
lamp:
if
the
lamp
lights,
indicating
the
ambient
temperature
is
higher
than
32
℃
.
“Sensor
fault”
indicating
lamp:
if
the
lamp
lights,
indicating
the
sensor
has
faulted.
“Power
interruption”
indicating
lamp:
if
the
lamp
lights,
indicating
the
interruption
of
power
line.
“Dirty
condenser”
indicating
lamp:
if
the
lamp
lights,
indicating
the
condenser
is
blocked
by
dirt,
and
needs
to
be
cleaned.
When
it
is
felt
that
the
difference
between
the
condenser
and
the
ambient
temperature
is
greater
than
or
equals
13
℃
(after
5
minutes
later),
“dirty
condenser”
indicating
lamp
lights,
accompanied
by
the
buzzer
alarm.
“Low
battery”
indicating
lamp:
if
the
lamp
lights,
indicating
the
low
battery
and
will
be
charged;
when
the
battery
is
connected
to
AC
power,
the
low
temperature
refrigerator
will
charge
it
automatically.
【Notes】
When
all
alarms
appear,
light
alarm
signal
will
immediately
flash
to
alarm
as
well
as
the
high
and
low
temperature
alarm
information.
15
minutes
after
light
flashing,
the
buzzer
begins
to
send
alarm
by
voice;
for
the
alarm
information
on
power
interruption
and
overvoltage,
the
buzzer
beings
to
send
alarm
by
voice
after
the
light
flashes
for
1
minute.
Under
the
power
interruption,
the
display
appears
black
screen,
without
any
other
information
displayed,
and
the
alarm
lamp
operates
under
alarm
mode.
After
the
black
screen
lasts
for
30
seconds,
the
display
panel
will
normally
display
for
5
seconds,
and
alternatively
display
as
per
this
mode.
For
alarm
information
on
dirty
condenser,
when
the
light
flashes,
the
buzzer
and
the
voice
will
send
alarm
at
the
same
time;
for
that
on
low
battery,
light
flashing
alarm
is
available,
without
buzzer
alarm;
for
that
on
too
high
Summary of Contents for DW-86L338
Page 7: ...7 88 Product appearance DW 86L388 486 628 728 828...
Page 8: ...8 88 DW 86L288 DW 86L338 388A...
Page 9: ...9 88 DW 86L490 DW 86W100...
Page 10: ...10 88 DW 86W420...
Page 11: ...11 88 Dimensions DW 86W100...
Page 12: ...12 88 DW 86L490...
Page 29: ...29 88 product nameplate For example DW 86L338...