40
/
88
【
Setting of special functions
】
1. Setting of password value
When
the
low
temperature
refrigerator
is
firstly
used,
unlock
password
is
06.
After
unlocking,
press
“Function
Selection”
and
“Buzzer
Cancel”
for
5
seconds
simultaneously,
06
will
be
displayed
on
the
display,
then
press
“
▲
”
and
“
▼
”to
adjust
the
password
values.
Password
value
can
be
chosen
among
05,
06,
07……29,
30.
No
operation
will
be
done
within
5
seconds
after
the
password
value
is
set,
then
it
will
enter
the
lock
status
automatically,
indicating
the
password
value
set
is
valid.
When
unlock
the
password
value,
the
display
figures
can
be
displayed
among
01,
02,
03……98,
99.
2. Setting of start delay
Under
the
unlock
status,
press
and
hold
down
“Function
Selection”
and
“
▽
”for
5
seconds
at
the
same
time.
Start
delay
of
high
temperature
compressor
is
01
(1
minute)
when
the
display
indicates
that
the
equipment
is
energized,
then
the
start
delay
can
be
set
as
01,
02,
03
‐‐‐‐‐‐
09,
10
(1
minute
‐
10
minutes)
by
pressing
“
“
△
or”
▽
“.
The
default
delay
is
1
minute.
3. Calibration function
Under
the
unlock
status,
press
and
hold
down
“Function
Selection”
for
5
seconds.
Temperature
calibration
value
will
be
displayed
on
screen
display
area,
at
this
time,
the
difference
between
display
temperature
and
that
at
the
special
point
inside
the
refrigerator
will
be
calibrated.
For
example,
display
temperature
is
‐
80
℃
and
temperature
at
a
special
point
is
‐
75
℃
,
then
+5
℃
can
be
input
to
change
the
display
temperature
into
‐
75
℃
,
therefore
the
calibration
range
is
±5
℃
.
4. Control of condensate fan
When
the
compressor
is
turned
on,
the
two
fans
also
will
be
turned
on;
when
the
two
compressors
are
turned
off,
the
two
fans
will
depend
on
the
following
conditions
for
on
or
off:
when
the
ambient
temperature
is
higher
than
20
℃
,
the
two
fans
will
be
turned
on;
when
it
is
lower
than
20
℃
(except
for
20
℃
),
one
fan
will
be
turned
off
and
the
other
will
be
turned
off;
when
the
ambient
temperature
is
lower
than
12
℃
(except
for
12
℃
),
the
Summary of Contents for DW-86L338
Page 7: ...7 88 Product appearance DW 86L388 486 628 728 828...
Page 8: ...8 88 DW 86L288 DW 86L338 388A...
Page 9: ...9 88 DW 86L490 DW 86W100...
Page 10: ...10 88 DW 86W420...
Page 11: ...11 88 Dimensions DW 86W100...
Page 12: ...12 88 DW 86L490...
Page 29: ...29 88 product nameplate For example DW 86L338...
Page 55: ...55 88 PICTURE 2 PICTURE 3 PICTURE 4 U Unit Pa 3Pa...