Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a
little mild detergent. Do not use gasoline or other solvents. Finally dry with a dry cloth.
Keep water heater dry.
To ensure high working efficiency, heating elements and tank liner of water heater
shall be cleaned once every three years. Take care not to damage the protection layer
on heating elements and tank liner surface. According to the local water quality,
magnesium rod shall be periodically replaced. If maintenance is needed, please
contact a local service station.
2
7
After installation, as the tank is empty in the first usage, be sure to open the tap water
inlet valve and mixing valve. When the tank is filled with water, and the shower nozzle or
other water outlet keeps the water output, please close the mixing valve, check if there
is water leakage at each joint and plug the power.
Turn the knob as per the needed water temperature. The mark of the knob increases
from water inlet temperature to 75
℃
æthe heating temperature steplessly. The heating
indicator will light on under heating mode. Generally, the knob should be set to the
highest scale. The water heater can regulate the temperature automatically. The power
will be switched off automatically when the set temperature is reached, and will be
switched on automatically when the temperature drops to a certain level. As it continues
heating, you can use hot water as well.
When the tap water inlet pressure arrives at or exceeds 0.80MPa, the drain hose of
safety valve will discharge a large amount of water. It is due to extra high water
pressure. Please contact the local after service agent for disposal.
In long-term out-of-use or maintenance of the heater, you can close the city water pipe
valve and set the mixing valve to the highest water temperature rate after opening the
safety valve handle. Move up the safety valve handle to drain the tank. To avoid injury,
before the next use, it is suggested to first open hot water valve before switching on the
water heater, exhaust gas possibly retained in the pipeline. In this case, no smoke or
fire is permitted near the open valve. Carefully check and confirm all parts are in good
condition.
水。
Usage
Usage
Cleaning and maintenance
Cleaning and maintenance
Rated voltage
V 230 230 230
Rated pressure
MPa
Rated temperature
Dimension
Waterproof grade
Mixing factor
Tap water pressure
Average temperature
of hot water outlet
Re-heating time
(temperature rise 50
℃)
Diameter of power wire
Outlet rate of hot water
24h fixed COP
Volume
Power
Net weight
Rated frequency
Hz 50 50
50
0.80
2000
2000
2000
0.80
0.80
W
K g
75
8
10
IPX4
No less than 0.05MPa
See to Figure 1
3×1.5
3×1.5
3×1.5
75
10
15
IPX4
75
14
25
IPX4
L
mm
mm
S
/
/
/
/
℃
%
2
Front view
Side view
b
Cutaway vie w
Rear vie w
d
e
Model
a b c d e
298
287
501
152
100
318
300
623
152
100
378
374
616
152
100
Remarks: The permitted error or limit of the above parameters is ±10%.
Remarks: The permitted error or limit of net weight above is ±10%.
A
Hot water outlet
F
Thermometer tube
G
Wall-mounting bracket
B
Cold water inlet
C
Tank
D
Heating element
E
Anode rod
Parameters
Dimensions
Parameters
Dimensions
a
c
E
A
B
D
C
G
F
(Figure 1)
ES10V-M1
ES15V-M1
ES25V-M1
See to Figure 1
See to Figure 1
No less than 0.05MPa No less than 0.05MPa
℃
ES10V
-
M1
ES15V
-
M1
ES25V
-
M1