Service Manual
Model No:ES10V-M1
2-3. Dimensions
Fig. 1
Chapter 3: Installation
3-1. Accessory parts
Part Name
Qty
-5-
3-2. Installation
1. Installation must be made by installers of or designated by our company after-service department.
The water heatershall be wall-mounted.
2. Before installation, make sure water heater rear wires are fit firmly. Determine an installation location.
Make 2 holes
Φ
12mm, 65 mm deep in the wall with an impact drill according to installating dimension.
Insert and fix expansion hooks in corresponding wall holes. Lift the water heater. Make wall rack
corresponding to the hooks. Hang the ring of the extended connection line onto a hook and hang the
wall rack(see Figure 2). Install accessories such as safety valve, drain hose as shown in Figure 3. Use
sealing compound to prevent water leakage.
3. To facilitate installation and removal, it is suggested a G 1/2" movable nut be fitted at appropriate
locations on inlet and outlet pipes respectively. Find the location requiring hot water supply. Connect
inlet pipe, outlet pipe and city water pipe respectively to the use point.
4. The hot water pipe shall not be too long to reduce the heat losses.
5. Please reserve some space in installation for the future maintenance.
Product Model
Electric
water
heater(Set)
Safety valve
Drain hose
(Unit)
Expansion
hook(PCS)
User’s
manual
(Copy)
ES10V-M1 1
1
2
1
ES15V-M1 1
1
2
1
ES25V-M1 1
1
2
1