background image

16

ASSEMBLE
CURTAINS/TOP
RAIL

2

PREPARE
WINDOW FOR
INSTALLATION

Inspect window track, sash, and sill
for its ability to support the weight of
air conditioner.

Measure width between window
moldings to ensure Instant Mount
will fit window frame. Instant Mount
models are designed for windows
wide (the detail see page

15)

Instant Mount kit supplied with unit
is designed for mounting in most
double-hung windows

without

storm windows.

For installation in

window frame with storm window,
modify sill by adding wood strips(not

to inner and outer sills. This

raises

storm window frame.

3

Mobile home window installation

Add wood strip (at least 1 1/2" wide)
along entire width of window sill.
Thickness of wood strip should match
height of front lip on window frame.
Fasten wood strip to sill with a
minimum of three countersunk wood
screws (not supplied with kit). This
provides a smooth surface for
mounting air conditioner.

Storm window installation

If storm window frame does not allow
adequate clearance below sill (1/2"
required), remove storm window
frame or create clearance by adding a
wood strip (at least 1 1/2" wide) along
entire width of sill. Fasten wood strip
to sill with at least three countersunk
wood screws (not supplied with kit).
This provides a smooth surface for
mounting air conditioner.

SILL

Wood

Strip

1/2"

Minimum

O
U

T

D
O
O
R

Storm Wi ndow
Frame

1 1/2"

Minimum

I

N
D
O
O
R

1 1/ 2"

Minimum

Wood

Strip

I

N
D
O
O
R

O
U

T

D
O
O
R

Window

Frame

Must be a minimum

of 1/2" to clear

bottom rail on unit

included)

unit and eliminates interference

of

Install top rail with four

screws.

13/32"

Slide left-hand curtain assembly
into left end of top and bottom
rails. Repeat for right-hand curtain
assembly. Fasten curtain retainer
strips to sides of outer case with

six 13/32" screws.

Summary of Contents for ESA3156 - ANNEXE 221

Page 1: ...0010555512 ESA3156 ESAX3186 ESA3245 ESA3185 Only HWR18VC5 HWR24VC5 ESA3156 ESAX3186 ESA3245 ESA3185...

Page 2: ...1...

Page 3: ...2...

Page 4: ...3 1 1 2 4 4 5 5 6 7 8 12 8 8 12 13 20 14 14 15 20 21 22 22 23 24...

Page 5: ...ss reset button 2 Press test button unit should trip 3 Press reset button again for use Do not use if above test fail In the event this device trips the cause of the malfunction is to be corrected bef...

Page 6: ...5...

Page 7: ...vent louvers vent controller 6 You have 3 levels of Fan Speed to set at your desired comfort level HIGH MED and LOW You can run the fan only on not so hot days The fan can be set to run at 3 speeds H...

Page 8: ...materials it purifies the air effectively Its wavy structure increases the capability to filter dust and smoke effectively Due to the retention of the active carbon it has a high purifying speed capab...

Page 9: ...8 TEMP TIME MODE SPEED TIMER ON OFF Remote control and control panel operations...

Page 10: ...TIME MODE SPEED TIMER ON OFF Every time you press the MODE button it will change between FAN COOL ENERGY SAVER and DEHUM See Fig 3 Having set the temperature you will set the function of the air condi...

Page 11: ...place between the set temperature 1 and 3 o F above the set temperature TEMP TIME MODE SPEED TIMER ON OFF Once the function mode is decided you will have to set the fan speed See fig 4 Every time you...

Page 12: ...the desired time use the pad key to lower the selection c After set TIMER ON LED display will show the time This time displayed unit will starts after X hours Timer off See Fig 5 Unit must be running...

Page 13: ...l Air Flow Direction Adjusting the vertical louvers left and right will change horizontal airflow Adjusting Vertical Air Flow Direction Adjusting the Horizontal vane up and down will change vertical a...

Page 14: ...13...

Page 15: ...ong flat head bolt and locknut top rail left and right side curtains 19 32 long screw and locknut window seal gasket curtain attachment screws 13 32 basepan angle wood screws 31 32 CR2025 battery Remo...

Page 16: ...WR18VC5 HWR24VC5 ESA3156 ESAX3186 ESA3245 ESA3185 Model A inch Dimension B inch C inch D inch Max Case High Case Width D inch Min Case Depth A B C HWR18VC5 HWR24VC5 ESA3156 ESAX3186 ESA3245 ESA3185 15...

Page 17: ...h a minimum of three countersunk wood screws not supplied with kit This provides a smooth surface for mounting air conditioner Storm window installation If storm window frame does not allow adequate c...

Page 18: ...ke screws easier to drive drill a pilot hole into sash through clearance hole in curtains Install three wood screws 31 32 top mounting rail screws Use two wood screws 31 32 to fix the case to windows...

Page 19: ...eful not to drill pilot hole too deep Add a piece of tape to the drill bit as a depth gauge Also stay clear of glass Be careful not to damage the function of the window Cut window seal gasket to width...

Page 20: ...19 Remove the 2 shipping screws on the top of the air conditioner that hold the chassis to the outer shell casing...

Page 21: ...20...

Page 22: ...y pulling off the exposed door on the top of the unit based on the installation 3 Pull the tab slightly to release the filter Pull the filter in the same direction as the opening 4 Clean the filter wi...

Page 23: ...22...

Page 24: ...23 See page 8 See page 17...

Page 25: ...24...

Reviews: