Page 3
31-5000736 Rev. 0
Technical Specifications - NF80DS
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Downflow
NF80D045S3A
44,000
36,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
113
NF80D070S3A
66,000
54,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
119
NF80D070S3B
66,000
54,000
80.00%
2 — 3
1/2
120-60-1
15
6.8
40
128
NF80D090S4B
88,000
72,000
80.00%
3 — 4
1/2
120-60-1
15
8.4
40
140
NF80D110S5C
110,000
90,000
80.00%
4 — 5
1/2
120-60-1
15
10.9
40
160
Note: For vent sizing and clearances to combustibles, please reference installation instructions.
MAJOR/MINOR REVISION
CABINET WIDTH
A - 14.5
B - 17.5
C - 21
NOMINAL CFM
3 - 1200 CFM
4 - 1600 CFM
5 - 2000 CFM
DESIGN VARIANT
S - ECM, 1-STAGE
BRAND
N - GE
PRODUCT
F - FURNACE, GAS
AFUE
APPLICATION
D - DOWNFLOW, STANDARD EMISSION
HEATING INPUT (1000 BTU/HR)
45, 70, 90, 110
N
N FF 80
80 D
D
SS 44 A
A XX
XX
110
110