Page 4
31-5000734 Rev. 0
NF80X060V3A BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed DIP
Switch Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1030
1140
+18%
965
1075
+12%
925
1020
+6%
870
965
Factory Default
825
915
-6%
775
865
-12%
735
810
-18%
685
760
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
595
715
815
920
845
1015
1175
1340
Factory Default
565
680
735
840
790
945
1070
1215
-
510
610
695
780
715
845
980
1120
NF80X080V4B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed DIP
Switch Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1350
1500
+18%
1270
1420
+12%
1200
1340
+6%
1130
1270
Factory Default
1060
1190
-6%
970
1130
-12%
880
1025
-18%
845
950
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
640
870
1030
1200
1020
1310
1535
1750
Factory Default
590
770
925
1100
935
1200
1400
1600
-
545
635
750
960
815
1080
1260
1430
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific
DIP Switch Settings.
2
Factory default setting.
NOTES
- The effect of static pressure is included in air volumes shown.
• First stage HEAT is approximately 91% of the same second stage HEAT.
• First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
• Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 280 for
NF80X060V3A and 380 cfm for NF80X080V4B.
• Zoning System Applications - Minimum blower speed is 250 cfm for NF80X060V3A and 380 cfm NF80X080V4B.
Blower Performance