Blower Performance
NF80X100V5C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed DIP
Switch Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1690
1855
+18%
1605
1765
+12%
1525
1675
+6%
1445
1585
Factory Default
1360
1495
-6%
1280
1405
-12%
1200
1315
-18%
1115
1230
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
1060
1220
1330
1565
1535
1710
1910
2210
Factory Default
970
1075
1180
1430
1400
1565
1715
2015
-
875
980
1070
1255
1260
1400
1560
1815
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific
DIP Switch Settings.
2
Factory default setting.
NOTES
- The effect of static pressure is included in air volumes shown.
• First stage HEAT is approximately 91% of the same second stage HEAT.
• First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
• Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 450 cfm.
• Zoning System Applications - Minimum blower speed is 450 cfm.