Page 4
31-5000727 Rev. 0
BLOWER PERFORMANCE DATA
Model
Motor
Size (hp)
Blower
Size
Heating
Temp.
Rise
(°F)
Heating CFM @ .10" - .80" w.c.
Cooling
Stage
Cooling CFM @ .10" - .80" w.c.
Speed
Adjust.
Setting
"D"
Setting
"C"
Setting
"B"
Setting
"A"
Setting
"D"
Setting
"C"
Setting
“B”
Setting
"A"
NF96D070V4B
3/4 11x10
35-65
High
Fire
1110
1305
1430
1700
2nd
Stage
1110
1340
1575
1800
+
995
1175
1315
1520
995
1230
1420
1650
Norm
880
1055
1170
1365
880
1085
1290
1460
-
25-55
Low
Fire
860
1020
1140
1340
1st
Stage
740
915
1055
1255
+
795
910
1030
1230
660
820
940
1120
Norm
680
825
910
1085
575
735
850
995
-
NF96D090V5C
1
11x11
40-70
High
Fire
1395
1555
1695
1825
2nd
Stage
1335
1600
1750
1980
+
1275
1395
1585
1670
1225
1450
1630
1830
Norm
1145
1265
1405
1525
1120
1270
1450
1660
-
30-60
Low
Fire
1130
1230
1365
1475
1st
Stage
955
1115
1265
1450
+
1040
1130
1250
1340
855
1005
1150
1285
Norm
910
1025
1130
1210
750
890
1060
1170
-
NF96D110V5C
1
11x11
45-75
High
Fire
1595
1795
1955
2010
2nd
Stage
1335
1585
1790
2010
+
1450
1615
1795
1865
1220
1440
1630
1865
Norm
1290
1460
1610
1680
1100
1275
1475
1680
-
35-65
Low
Fire
1165
1305
1465
1547
1st
Stage
920
1095
1265
1440
+
1055
1185
1315
1404
830
965
1130
1290
Norm
930
1070
1180
1272
735
860
1035
1155
-