507962-01G / 31-5000654
Page 47 of 51
Issue 2149
Model
Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
NF96D110V5C
High Fire
35 - 65
+
1595
1795
1955
2140
Normal
1450
1615
1795
1975
-
1290
1460
1610
1795
Low Fire
20 - 50
+
1165
1305
1465
1625
Normal
1055
1185
1315
1475
-
930
1070
1180
1320
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D”
Setting “C”
Setting “B”
Setting “A”
2nd Stage
+
1335
1585
1790
2010
Normal
1220
1440
1630
1865
-
1100
1275
1475
1680
1st Stage
+
920
1095
1265
1440
Normal
830
965
1130
1290
-
735
860
1035
1155
Allowable Heating Speeds
Model Number
Speed Adjust
Setting "D"
Setting "C"
Setting "B"
Setting "A"
NF96D070V4B
+10%
Allowed
Allowed
Allowed
Allowed
Norm
Allowed
Allowed
Factory Setting
Allowed
-10%
Allowed
Allowed
Allowed
Allowed
NF96D090V5C
+10%
Allowed
Allowed
Allowed
Allowed
Norm
Allowed
Allowed
Factory Setting
Allowed
-10%
Allowed
Allowed
Allowed
Allowed
NF96D110V5C
+10%
Allowed
Allowed
Allowed
Allowed
Norm
Allowed
Allowed
Factory Setting
Allowed
-10%
Allowed
Allowed
Allowed
Allowed
Table 18.
Allowable Circulation Speeds
Model Number
38% of Second Stage Cooling
All Models
Factory Setting
Table 19.