Before calling for service, please first read the following table. This could save
you time and money. In this table, common problems are discussed which can
be corrected with minor adjustments by you.
TROUBLESHOOTING
Problem
Cause
Solution
The
compressor
doesn’t work
• The refrigerator is in deep
freeze cooling.
• The refrigerator isn’t
powered on.
• The fuse or the circuit
breaker for room has
tripped off.
• There is no line electricity.
• This case is normal for a fridge
automatically. The period of
deep freeze cooling lasts about
30 minutes.
• Make sure the power cord
plug is inserted all the way into
the power outlet.
• Check and change to a new
15A fuse and/or reset the
circuit breaker.
• Check the power line in the
room. Call the local electric
company.
The fridge
runs
frequently
or runs for a
long time.
• The room temperature or
outside temperature is too
high.
• The automatic icemaker is
in operation.
• The doors or drawers are
frequently being opened
and closed.
• The control settings are
settings in freezer and
fresh food are set to a cold
level.
• Door and/or drawer
gasket seals may be dirty,
frayed, or cracked.
• The condenser is dirty.
• In this case it is normal for the
fridge to operate continuously.
• This is normal since the
icemaker adds an extra
workload in the fridge.
• Try to reduce frequency of
door or drawer openings.
• Raise up the compartment
temperatures slightly and
allow 24 hours to reach
new balance.
• Clean off the gaskets and/or
heat slightly with hair dryer so
gasket takes contour of metal
frame.
• Clean the condenser.
The temperature is too low.