10 to 12 SEER  3 to 5 Tons

HB3600VC1M25    HB4200VA1M25

 Installation & Operation Manual

 Air Handler

   HB6000VA1M25    HB6000VC1M25

    HB4800VA1M25

WARNING

WHEN THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA, SUCH AS

A GARAGE OR UTILITY ROOM, WITH ANY CARBON MONOXIDE PRODUCING

DEVICES (i.e. AUTOMOBILE, SPACE HEATER, WATER HEATER,ETC.) INSURE

THAT THE ENCLOSED AREA IS PROPERLY VENTILATED.

WARNING

CARBON MONOXIDE (REFERED TO AS CO) CAN CAUSE PERSONAL INJURY

OR DEATH

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS, LOCAL CODES OR NATIONAL

CODES MAY CAUSE FIRE, EXPLOSION, ELECTRICAL SHOCK, PERSONAL

INJURY OR PROPERTY DAMAGE.

FOLLOW ALL LOCAL CODES. IN THE ABSENCE OF LOCAL CODES REFER TO :
                                  

   NATIONAL ELECTRICAL CODE NFPA 70

                                     NFPA 90A & 90B
                                     UNIFORM MECHANICAL CODE

READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING TO INSTALL
OR SERVICE THIS APPLIANCE.

ONLY FACTORY AUTHORIZED KITS OR ACCESSORIES SHOULD BE USED WHEN
INSTALLING OR MODIFYING THIS APPLIANCE, UNLESS OTHERWISE NOTED IN
THESE INSTRUCTIONS.

SOME LOCALITIES MAY REQUIRE THE INSTALLER/SERVICER TO BE LICENSED.
IF IN DOUBT CONTACT YOUR LOCAL AUTHORITIES.

These instructions should be retained and kept adjacent to the unit for future reference.

MODEL #  HB                00VA1M25

MODEL #  HB                00VC1M25

INSTALLATION DATE

The information contained in this booklet is subject to change without notice.

No. 0010575351
            E

Models:

Summary of Contents for HB3600VC1M25

Page 1: ...CK PERSONAL INJURY OR PROPERTY DAMAGE FOLLOW ALL LOCAL CODES IN THE ABSENCE OF LOCAL CODES REFER TO NATIONAL ELECTRICAL CODE NFPA 70 NFPA 90A 90B UNIFORM MECHANICAL CODE READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING TO INSTALL OR SERVICE THIS APPLIANCE ONLY FACTORY AUTHORIZED KITS OR ACCESSORIES SHOULD BE USED WHEN INSTALLING OR MODIFYING THIS APPLIANCE UNLESS OTHERWISE NOTED IN THESE INSTR...

Page 2: ...the passage of new laws it is recommended that any work on this unit be done so by a certified technician Should questions arise contact the local EPA office THIS APPLIANCE IS NOT APPROVED FOR OUTDOOR INSTALLATION THIS APPLIANCE IS NOT TO BE USED AS A CONSTRUCTION HEATER GENERAL This appliance was designed certified and must be installed in accordance with published codes In the absence of local c...

Page 3: ...INLET RIGHT SIDE VIEW LIQUID LINE SUCTION LINE A B E 12 2 31 cm 0 8 2 1cm PHYSICAL DIMENSIONS A B C D E F G H J K 53 3 22 1 23 5 25 2 9 1 8 3 4 7 22 2 19 8 3 6 135 5cm 56 1cm 59 8cm 64 0cm 23cm 21 2cm 12cm 56 5cm 50 4cm 9 05cm 3 For HB3600VC1M25 A B C D E F G H J K 59 4 22 1 23 5 25 2 9 1 8 3 4 7 22 2 19 8 3 6 151cm 56 1cm 59 8cm 64 0cm 23cm 21 2cm 12cm 56 5cm 50 4cm 9 05cm For HB42 6000VA1M25 HB6...

Page 4: ...aced under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner This secondary drain pan is required in the event that there is a leak or main drain blockage Closed cell insulation should be applied to the drain lines in unconditioned spaces where sweating may occur Appliances installed in garages warehouses or other areas where they may be subj...

Page 5: ...eft Discharge Tube and Drain conn front see page 6 Important Remove the horizontal pan when unit is installed in unconditioned i e Garage Attic application or downflow applications and install insulation kit on vertical donut shape drain pan Upflow Discharge Air Handler is factory ready for Upflow Horizontal Right Discharge Application as shown 5 ...

Page 6: ...ar of the cavity and assure it slips into channel bracket at the rear of the cavity 6 Replace the J shape metal bracket or brackets on the vertical drain pan and place the plastic oval gasket on horizontal drain pan Reinstall access panels and flowrator making sure not to over torque screws Snap in the drain cover on the right lower service panel 7 The Airhandler can now be placed in its left hori...

Page 7: ...g 3 This will reduce the potential for water blow off into the air stream 5 Slide the coil assembly into Air Handler and reattach the metal coil retainer bracket to tie bracket See Fig 2 Then reattach the upper access panel followed by the two lower access panels to match the tubing and drains 6 A 4 to 3 removable panel is recommended at the point where the duct meets with the return part of the A...

Page 8: ... will prevent damage to the plastic drain pan A joint compound should be used to prevent leakage and act as a lubricant When using copper tubing as a condensate line adequate caution muat be taken to prevent damage to the plastic drain pan during the soldering process All condensate drain lines and drain traps should be adequately insulated The unit and the auxiliary drain pan must be adequately e...

Page 9: ...he rating plate included in the optional heat kit must be applied to the Air Handler as indicated The use of copper connections are recommended inside the control box see UL 1995 section 37 9 WARNING A MEANS OF STRAIN RELIEF MUST BE INSTALLED TO THIS APPLIANCE AT THE ELECTRICAL SERVICE ENTRANCE When an optional electric heat kit is installed refer to the electrical requirements for that kit The am...

Page 10: ...oor unit at the same time no air supply mode If need select the air supply mode switch can adopt multi connect switch or select switch The detailed infor see the following diagram 3 Above diagram Outdoor Unit Connection Left Indoor and Outdoor unit power supply Respectively Right Indoor unit power supply COM BL YL BL TRANSFORMER 24V RD TO FAN RELAY CONTROL Y C TO OUTDOOR UNIT R C Y O SELECT SWITCH...

Page 11: ...is mode is control the indoor unit cooling only outdoor unit at the same time no air supply mode If need select the air supply mode switch can adopt multi connect switch or select switch The detailed infor see the following diagram 6 Above diagram Outdoor Unit Connection Left Indoor and Outdoor unit power supply Respectively Right Indoor unit power supply COM BL RD TRANSFORMER 24V RD TO FAN RELAY ...

Page 12: ...e the 13 16 nut into position Braze tailpiece to the liquid tube 7 Insert the suction line into the connection slide the insulation and the rubber grommet at least 18 away from the braze joint 8 AFTER THE TAILPIECE HAS COOLED position the white Teflon seal and hand tighten the nut 9 Torque the 13 16 nut to 10 30 ft lbs or tighten 1 6 turn 10 Replace suction line grommet and insulation 12 CIRCULATI...

Page 13: ... return temperature from the supply temperature This is referred to as the temperature rise 6 Measure the actual supply voltage and actual amperage at the terminal block circuit breaker 7 The BTUH output Voltage x Amps x 3 41 CFM output BTUH 1 08 X temperature rise Should the CFM need to be increased or decreased it may be done by adjusting the blower speed tap as shown on the wiring diagram 13 Mo...

Page 14: ...alled in a garage or where flammable vapors may be present Unit is protected from vehicular or other physical damage Return air is not to be obtained from any areas where there may be objectionable odors flammable vapors or products of combustion such as carbon monoxide CO which may cause serious personal injury or death REGULAR MAINTENANCE DISCONNECT ALL POWER SUPPLIES BEFORE PERFORMING ANY SERVI...