Figure 1
Minimum Circuit Amps
15 25 25 30 40 35 40 60 60
Rated Load Amps 7.4 9.6 11.8 13.0 16.7 15.8 18.7 26.6 28.9
Compressor Locked Running
Amps 48 60 73 85 105 90 135 155 165
Full Load Amps 0.86 1.4 1.4 1.43 1.43 1.43 1.43
Fan Motor Rated HP 1/8 1/5 1/5 1/3 1/3 1/3 1/3
Nominal RPM 850 1075 1075 1075 1075 1075 1075
Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8" [9.52] 3/8"[9.52] 3/8"[9.52]
Vapor Line OD - In (mm) 5/8"[15.88] 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2]
R-22 Charge -Oz (g) 74.2 [2100] 91.87[2600] 88.34[2500] 102.47[2900] 132.51[3750] 125.44[3550]
Net Dimensions - In (mm) 23*23*27 3/4 23*23*27 3/4 23*23*31 1/2 30 1/4*30 1/4*27 3/4 30 1/4*30 1/4*35 1/2 301/4*30 1/4*35 1/2 30 1/4*30 1/4*31 1/2
W*D*H [585* 585*705] [585* 585*705] [585* 585*805] [770 *770*705] [770 *770*905] [770 *770*905] [ 770 *770*805]
Shipping Dimensions - In (mm) 25*25*32 1/4 25*25*32 1/4 25*25*36 32 3/4*32 3/4*32 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*36
W*D*H [632* 632*819] [632* 632*819] [632* 632*919] [832*832*830] [832*832*1030] [832*832*1030] [832* 832*930]
Net Weight - Lbs (kg) 123[56] 125[57] 139[63] 196[89] 231[105] 238[108] 298[135]
Approx Shipping Weight - Lbs (kg) 141[64] 143[65] 152[69] 222[101] 257 [117] 264[120] 321[146]
183.75[5200]
The dimensions for the condensing unit are illustrated in
Figure 1
. Physical and electrical
specifications are provided in
Table 3
for 12 SEER systems respectively.
3
H
W
D
Table 2:System Cooling Capacity
Outdoor Unit With This Indoor Air handler
Model Number
HC18A1VAR HB2400VA1M20
HC24A1VAR HB2400VA1M20
HC30A1VAR HB3000VA1M20
HC36A1VAS HB3600VA1M20
HC42A1VAR HB4200VA1M25
HC48A1VAR HB4800VA1M25
HC60A1VAR HB6000VA1M25
Air Handler
Cooling Capacity (Btu/h) SEER Rated
Sensible Total CFM(Outdoor)
13000
17000
20000
24000
1850
1850
1950
1950
18000
24000
28000
34000
10
10
10
10
28400
29160
33120
2700
2700
2900
40000
40500
46000
10
10
10
33120
40170
40180
2900
2900
2900
46000
55800
56000
10
10
10
Compressor
brand
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
Sanyo
Sanyo
Sanyo
H23R
H20R
H29A
H23R
H29A
H20J
28.8
145
2.5
60
1/2
171.38[4850]
120.14[3400]
127.21[3600]
Model:HC18-60C1VAR
Table 3:
MODEL:
HC18C1VAR HC24C1VAR
HC30C1VAR
HC36C1VAR
HC42C1VAR
HC48C1VAR
HC60C1VAR
Unit Supply Voltage
Normal Voltage Range
208/230-1-60
197 - 253
Compressor Brand
Bristol
Bristol
10.1
13.4
16.2
17.7
22.3
21.2
34.7
24.8
37.6
38.5
Max Fuse or Max CKT. BKR.
(HACR per NEC )
Summary of Contents for HC18D1VAR