! WARNING

These instructions are intended as an aid to qualified, licensed service personnel for proper installation,
adjustment and operation of this unit. Read these instructions thoroughly before attempting installation
or operation. 

Failure to follow these instructions may result in improper installation, adjustment,

service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury
or death.

This product is designed and manufactured to permit installation in accordance with National Codes. 

It

is the installer's responsibility to install the product in accordance with National Codes and/or
prevailing local codes and regulations

. The manufacturer assumes no responsibility for equipment installed

in violation of any codes or regulations.

The United States Environmental Protection Agency (EPA) has issued various regulations regarding
the introduction and disposal of refrigerants in this unit.

 Failure to follow these regulations may harm

the environment and can lead to the imposition of substantial fines. Because these regulations may vary
due to the passage of new laws we suggest that any work on this unit be done by a certified technician.
Should you have any questions please contact the local EPA office.
The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the
attachment or use of any components, accessories or devices (other than those authorized by the manufacturer)
into, onto, or in conjunction with the air conditioner. 

You should be aware that the use of unauthorized

components, accessories or devices may adversely affect the operation of the air conditioner and
may also endanger life and property

. The manufacturer disclaims any responsibility for such loss or

injury resulting from the use of such unauthorized components, accessories or devices.

Attach the service panel to the outdoor unit securely

. If the service panel is not attached securely, it

could result in a fire or an electric shock due to dust, water, etc.
These instructions are intended as an aid to qualified, licensed service personnel for proper installation,
adjustment and operation of this unit. Read these instructions thoroughly before attempting installation
or operation. 

Failure to follow these instructions may result in improper installation, adjustment,

service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury
or death.

This product is designed and manufactured to permit installation in accordance with National Codes. 

It

is the installer's responsibility to install the product in accordance with National Codes and/or
prevailing local codes and regulations

. The manufacturer assumes no responsibility for equipment installed

in violation of any codes or regulations.

The United States Environmental Protection Agency (EPA) has issued various regulations regarding
the introduction and disposal of refrigerants in this unit.

 Failure to follow these regulations may harm

the environment and can lead to the imposition of substantial fines. Because these regulations may vary
due to the passage of new laws we suggest that any work on this unit be done by a certified technician.
Should you have any questions please contact the local EPA office.
The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the
attachment or use of any components, accessories or devices (other than those authorized by the manufacturer)
into, onto, or in conjunction with the air conditioner. 

You should be aware that the use of unauthorized

components, accessories or devices may adversely affect the operation of the air conditioner and
may also endanger life and property

. The manufacturer disclaims any responsibility for such loss or

injury resulting from the use of such unauthorized components, accessories or devices.

Attach the service panel to the outdoor unit securely

. If the service panel is not attached securely, it

could result in a fire or an electric shock due to dust, water, etc.

Message to Owner

These instructions should be carefully read and kept near the product for future reference. While the instructions are
addressed primarily to the installer, useful maintenance information is included. Have your installer acquaint you with
the operating characteristics of the product and periodic maintenance requirements.

Summary of Contents for HC60A1VAR

Page 1: ...4 K 10 to 13 SEER 1 5 to 5 Tons Models HC18 60A1VAR S HC18 60C1VAR HC18 60D1VAR Installation Operation Manual Central Air Conditioner The information contained in this booklet is subject to change wit...

Page 2: ...service personnel for proper installation adjustment and operation of this unit Read these instructions thoroughly before attempting installation or operation Failure to follow these instructions may...

Page 3: ...on can result in unsatisfactory operation or dangerous conditions Carefully read this manual and any instructions packaged with separate equipment required to make up the system prior to installation...

Page 4: ...s 48 60 73 88 Full Load Amps 0 86 0 86 1 4 1 4 Fan Motor Rated HP 1 8 1 8 1 5 1 5 Nominal RPM 850 1000 1075 1075 Liquid Line OD In mm 3 8 9 52 3 8 9 52 3 8 9 52 3 8 9 52 Vapor Line OD In mm 5 8 15 88...

Page 5: ...196 89 231 105 238 108 298 135 Approx Shipping Weight Lbs kg 141 64 143 65 152 69 222 101 257 117 264 120 321 146 183 75 5200 The dimensions for the condensing unit are illustrated in Figure 1 Physica...

Page 6: ...705 770 770 805 770 770 805 770 770 905 770 770 805 770 770 905 Shipping Dimensions In mm 24 3 4 24 3 4 36 32 3 4 32 3 4 32 1 2 32 3 4 32 3 4 36 32 3 4 32 3 4 36 32 3 4 32 3 4 40 1 2 32 3 4 32 3 4 36...

Page 7: ...rical power to the unit before servicing Disconnect power to both the indoor and outdoor units NOTE There may be more than one electrical disconnect switch Failure to shut off power can cause electric...

Page 8: ...s are made from the service access area The most common application will find the unit best located about 10 from back wall with connection side facing the wall This application minimizes exposed tubi...

Page 9: ...ot kink or twist the tubing Refrigerant piping should not be installed in a cement slab as this limits access to the refrigerant should a leak be suspected To ensure good oil return to the compressor...

Page 10: ...valves are closed to contain the charge within the unit Do not force the valve stem against the retaining ring If the valve stem is backed out past the retaining ring system pressure could force the...

Page 11: ...hich increases power consumption and reduces performance The presence of moisture in a system can render it inoperable in a very short time Proper evacuation assures a dry uncontaminated system Here i...

Page 12: ...d do not connect many devices to one AC outlet It could cause a fire or an electric shock due to defective contact defective insulation exceeding the permissible current etc Perform electrical work ac...

Page 13: ...e for disconnecting power service to the unit The condensing unit control wiring requires a 24 Volt minimum 25 VA service from the indoor transformer as shown on the wiring diagram 7 SYSTEM STARTUP 1...

Page 14: ...ions it can take up to 2 hours for this overload to reset Make sure overload has had time to reset before condemning the compressor 9 MISCELLANEOUS 9 1 Replacement Parts Contact your local distributor...

Page 15: ...lary tubes Replace coil assembly Low vapor cool Low evaporator airflow Increase blower speed or reduce restriction replace air filter compressor iced Operating below 65 F outdoors Add low ambient kit...

Page 16: ...C BL BL YL YL Y 2 YL P3 P2 P1 6 RD R L1 GND L2 BK BK WH C S CC 4 RD YL 2 1 NC Optional Low High Pressur e Switches LPS HPS Compress or Protect 3 Min Time Delay BCAP RD LO RD L2 RD OR BK HI M IBM 3 GR...

Page 17: ...Made in P R C...

Reviews: