11
4. With one person holding the back panel, thread the end of the power cord
through the strain relief.
a
b
c
a
UL Listed Strain Relief
b
Back Panel
c
Power Cord
NOTE: Allow enough slack to connect the wires to the terminal block.
a
b
c
e
f
g
d
a
Terminal Block
b
Jumper Wire
c
Ground Screw
d
Power Cord Wires
e
Strain Relief Nut
f
UL Listed Strain Relief
g
Back Panel
5. Remove the ground screw. Place the green ground wire from the power cord on
top of the green ground wire from the range, replace screw and tighten.
6. Using 10-32 hex nuts, connect the red and black wires from the power cord to
the outer posts of the terminal block with the corresponding red and black wires
from the range.
7. Tighten the hex nuts completely, and then verify the connection.
NOTE: For power supply cord replacement, use only a power cord rated at
250 volts minimum, 40- or 50-amps that is marked for use with nominal 13/8"
(3.5 cm) diameter connection opening, with ring terminals and marked for use
with ranges.
8. Position the back panel against the back of the range, but do not fasten.
9. Gently, pull the excess power cord to the outside.