25
4. Screw the regulator cap back into the regulator and reattach the regulator to the
nipple and flare union.
STEP 2 - CHANGE BURNER ORIFICES
IMPORTANT: Carefully read and observe each orifice label for correct location. See
the Burner Chart earlier in this section.
NOTE: First remove all orifices and then start replacing them. This will help avoid the
possibility that some may not be replaced.
1. Remove the burner grates, burner caps and burner heads.
2. Using a 7 mm nut driver, remove the burner orifices.
a
a
Orifices
Triple Ring Burner
5 Orifices
Auxiliary Burner
Semi-Rapid Burner
Rapid Burner
1 Orifice Each
3. Install the proper orifices in the exact locations as noted in the previous graphic.
4. Replace the burner bases, heads, caps and top grates. Make sure burner caps are
properly seated on the burner head.