22
LP/PROPANE GAS CONVERSION
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped from
the factory for use with natural gas. A kit for converting to LP gas is supplied with
your cooktop. The kit is marked “FOR LP/PROPANE GAS CONVERSION”.
When the cooktop is converted for liquid petroleum (LP) gas, the LP gas supply is
required to provide a minimum of 10" to a maximum of 14" water column to the
cooktop regulator.
The conversion must be performed by a qualified service technician in accordance
with the kit instructions and all local codes and requirements. Failure to follow
instructions could result in serious injury or property damage. The qualified agency
performing this work assumes responsibility for the conversion.
24" Burner and Orifice Characteristic Table
Burner
Position
Orifice
Gas
Pressure Rate
Diam. (mm) Type
[i.w.c.]
[BTU/h]
Auxiliary
Front R
0.9
NG
4"
5000
0.58
LP (Propane)
10"
5000
Semi-Rapid
Rear L
1.17
NG
4"
6859
0.75
LP (Propane)
10"
6859
Triple
Front L
0.93 + 1.82
NG
4"
17357
1.14 + 0.56
LP (Propane)
10"
15000
Rapid
Rear R
1.6
NG
4"
6859
1.03
LP (Propane)
10"
6859
NOTE: The triple burner has only two injectors, one injector mounted in the center
and one mounted below the cover plate. To access the second injector, remove the
two screws and the cover plate.
a
a
a
Opening in grate for wok ring (provided) is located over left front burner.