11
Maintenance Service and Trouble Shooting
1 When the refrigerator does not get cold at all
NO
NO
Faulty compressor unit
- compressor
- refrigerator cycle
Compressor
- motor lock
- inter-lay short of motor
Starting relay
Electrolytic capacitor
(at 115V)
The refrigerator remains unchilled
even after the compressor is
operational for more than 30 minutes.
YES
(1)Disconnect the power.
(2)Remove the leads from caprcitor
and,as a precaution discharge it by shorting
the terminals with an insulated screw driver.
!
No continuity between terminals.
If normal,resistance drops to 0
temporarily & then rises to infinity.
In upside down position,check for
continuity between terminal(2 and 6).
YES
YES
Cause of trouble
NO
NO
Overload protector
Starting relay
Thermostat
Indication
Check point
YES
Does
compressor run?
YES
Is power
supplied to the
compressor?
NO
NO
Instruction(diagnosis)
In upright position,check for
continuity between terminals(2
and 5).
Check for continuity between
terminals(1 and 3).
YES
YES
YES
Check it for continuity
Program Diagram
Maintenance Service and Trouble Shooting