background image

English

3

Accessories

Range Hood Accessories Provided:

1 Range Hood

1 Damper Flap

4 Damper Screws

4 Range Hood Screws

4 Washers

2 Wire Connectors 

1 Aluminum Filter       

1 Charcoal Filter

1 User Manual

1 Vent Cover

Check to make sure that all parts and accessories are present and in good
condition. If you find that they are not in good condition or are missing, please
contact our customer service department for assistance.  

Our Toll-Free number

is 1-877-337-3639.

Table Of Contents

PAGE

Safety Precautions ............................................................................................1

Accessories ......................................................................................................3
Installation Preparation......................................................................................4
Selecting Venting Direction ................................................................................5
Cabinet Preparation for Hoods Support..............................................................6
Preparing Electrical Connections ........................................................................6
Preparing Duct Connections ..............................................................................7
Wiring Diagrams..............................................................................................8
Installing Ductwork............................................................................................8
Hood Installation ..............................................................................................9

Use and Care ................................................................................................10
Troubleshooting ..............................................................................................11
Warranty Information......................................................................................12

Summary of Contents for HHX2030

Page 1: ...User Manual Model HHX2030 Guide de l Utilisateur HHX2030 Manual del Usuario Modelo HHX2030 Range Hood Extractor de Aire Hotte de Cuisiniere Haier ...

Page 2: ...placing an existing range hood with your new Haier Range Hood turn OFF the electrical power to the existing unit before removal 10 Before servicing or cleaning the unit turn the power OFF at the service panel and if possible lock the service panel to prevent power from being switched on accidentally When the service disconnecting cannot be locked securely fasten a prominent warning device such as ...

Page 3: ...et Then turn OFF the burner BE CAREFUL TO AVOID BURNS If the flames are not put out immediately evacuate and call the fire department 4 Use an extinguisher only if a You know that you have a Class ABC extinguisher and you already know how to use it b The fire is small and contained in the area where it started c The fire department is being called d You can fight the fire with your back to an exit...

Page 4: ...ou find that they are not in good condition or are missing please contact our customer service department for assistance Our Toll Free number is 1 877 337 3639 Table Of Contents PAGE Safety Precautions 1 Accessories 3 Installation Preparation 4 Selecting Venting Direction 5 Cabinet Preparation for Hoods Support 6 Preparing Electrical Connections 6 Preparing Duct Connections 7 Wiring Diagrams 8 Ins...

Page 5: ...nd level for marking range hood location Hand saw or jig saw for cutting the wall or cabinet openings Duct tape Electrical tape Connector Clamp General Preparation Caution Please be sure to turn the electrical power switch OFF before beginning the installation 1 Remove the range hood from the carton 2 Lay the range hood upside down on a table covered with either cardboard or paper to prevent scrat...

Page 6: ...ided there are no obstructions such as wall joists or places where openings are difficult to make If a wall cap is used directly off the back of the hood special care must be taken to ensure that the damper in the damper duct connector on the hood and the damper in the wall cap do not interfere with each other when the range hood is operating This could result in either inadequate air delivery or ...

Page 7: ...on the bottom of the cabinet where the range hood will be mounted The wood strips should line up with the 4 keyhole slots on the top of the range hood Fasten the wood strips with wood screws about 3 in from each end Note The thickness of the wood strips should be slightly more than the recessed dimension The length should be cut to size 2 Measure and mark the electrical wiring opening in the wall ...

Page 8: ...ckout by inserting a screwdriver under one end and prying it up Then snip or break the attachment points 2 Install the damper assembly to the range hood with the 2 screws supplied 3 If discharge is vertical through a rectangular duct remove the knockout sections D B and E only 4 If the vertical discharge is through a 7 round duct remove knockout sections A and B and C only Note Section D and E rem...

Page 9: ... if the number of elbow and the length of the duct are kept to a minimum The back draft damper flap attached to the damper frame assembly which is supplied with the hood does not impede airflow significantly You may leave this in place even if you install a wall or roof cap with another back draft damper ...

Page 10: ...ent length in the hood to connect the field wires to the hood wires 4 Make the electrical connections using screw on wire connectors Attache the black wires together and then the white wires together and then the green or bare wire to the green grounding screw in the hood Replace the wiring compartment cover Caution All wiring installation must comply with local and national electrical code regula...

Page 11: ...omes saturated Check with your local retailer or dealer to purchase Light Bulb Do not use light bulbs that are brighter than 40 watts Exterior Surface Wipe the range hood exterior with a soft cloth and a mild detergent suitable for painted surfaces Do NOT use abrasive materials such as steel wool pads or scouring powders Repair or Replacement Parts Warning Disconnect range hood from the electrical...

Page 12: ... install metal ductwork from the range hood through either an outside wall or the roof If air is not blowing from the front vent openings check inside the cabinet above the range hood If you see a metal duct leading away from the vent hood then you have a system that vents to the outdoors If you do not see a duct your unit may be venting through the back wall Light does not turn on but fan turns o...

Page 13: ...D PUERTO RICO THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than an authorized dealer or service center Labor service transportation and shipping charges for the removal of defective parts and for installation of a replacement part beyond t...

Page 14: ...rticle veuillez contacter le Centre satisfaction client de Haier au 1 877 337 3639 UNE PREUVE D ACHAT DATÉE LE NUMÉRO DU MODÈLE ET LE NUMÉRO DE SÉRIE SONT OBLIGATOIRES POUR BÉNÉFICIER DE LA COUVERTURE OFFERTE PAR LA GARANTIE IMPORTANTE No Devuelva Este Producto al Establecimiento Compra Si tiene problemas con este producto por favor póngase en contacto con el Centro Haier de Atención al Cliente en...

Reviews: